一种高灵敏度,无层化可伸缩的温度传感器阵列,用于在医疗保健应用中进行皮肤上无线温度监测和映射
Aya Hekmet Makki1, Jae Gyu Jang2, Taeheon Kim3
1Research Institute of Computer, Information, and Communication, Pusan National University, Busan 46241, Republic of Korea.
ACS applied materials & interfaces
|October 17, 2025
概括
研究人员开发了一种高度灵敏,可伸缩的温度传感器,用于实时健康监测. 这种可穿戴设备提供准确的皮肤温度读数,有助于早期发现疾病和个性化医疗保健.
科学领域:
- 材料科学 材料科学 材料科学
- 生物医学工程 生物医学工程
- 传感器技术 传感器技术
背景情况:
- 实时皮肤温度监测对于早期疾病检测至关重要,需要先进的传感器.
- 现有的传感器往往缺乏所需的灵敏度,速度,线性或生物相容性,以适用于不引人注目的可穿戴应用.
研究的目的:
- 开发一种内在可拉伸,高灵敏,快速响应的热阻抗式温度传感器.
- 将传感器集成到可穿戴系统中,用于实时温度映射和健康监测.
主要方法:
- 使用聚硫酸 (PEDOT:PSS) /聚氨分散复合材料制造可伸缩的热阻传感器.
- 传感器性能的表征,包括灵敏度,线性,响应时间和应变下的机械稳定性.
- 将传感器集成到无线3x3阵列中,并开发用于数据可视化的智能手机应用程序.
主要成果:
- 传感器表现出高灵敏度 (-1.1% °C-1),高分辨率 (0.1 °C) 和出色的线性 (R2 ≈ 0.98).
- 实现了25-50°C之间的快速响应 (8.5秒) 和恢复 (5.2秒) 时间.
- 传感器在10,000个循环中在30%的应变下保持稳定的运行,使用无层制造工艺.
结论:
- 开发的可伸缩温度传感器满足了可穿戴医疗保健应用的关键要求.
- 无层制造简化了生产,提高了不引人注目的健康监测系统的可靠性.
- 无线传感器阵列和智能手机应用程序可实现实时温度映射和数据可视化,以改善患者护理.
相关概念视频
Temperature Measurement Sites
3.2K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
3.2K
Assessing Body Temperature - Oral
1.4K
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
1.4K
Assessing Body Temperature - Temporal Artery
1.1K
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
1.1K
Equipments Used to Measure Body Temperature
1.7K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.7K
Assessing Body Temperature - Axilla
1.2K
Procedural Guide for Assessing Axillary Body Temperature using a Digital Thermometer:
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
1.2K
Assessing Body Temperature - Tympanic membrane
1.1K
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
1.1K


