开发和验证一个高带宽的同轴壁流监测器,用于亚纳秒光束束特性表征
Monika Phogat1,2, Jose V Mathew1,2, Rajesh Kumar1,2
1Ion Accelerator Development Division, Bhabha Atomic Research Centre, Mumbai 400085, India.
The Review of scientific instruments
|October 22, 2025
概括
一个新的同轴壁流监测器 (C-WCM) 精确地测量了像LEHIPA这样的加速器的亚纳秒质子束束. 这种紧的双功能设备还可以作为光束位置监视器,增强加速器操作.
科学领域:
- 加速器物理学的物理学
- 颗粒束诊断 颗粒束诊断
- 高频电子产品 高频电子
背景情况:
- 高强度质子加速器需要精确的,非破坏性的光束特征.
- 现有的诊断系统在亚纳秒束束分析方面遇到了困难.
- 低能高强度质子加速器 (LEHIPA) 需要对其~100 ps RMS束束进行先进的诊断.
研究的目的:
- 设计,制造和验证一个紧的,宽带的,双功能的同轴壁流监测器 (C-WCM).
- 为像LEHIPA这样的加速器实现精确的亚纳秒束特性.
- 将集束长度和光束位置监测集成到一个单一的诊断工具中.
主要方法:
- 使用电磁模拟来优化C-WCM几何.
- 设计了一个没有铁的同轴结构,有八个高带宽输入通道.
- 进行了实验室射频表征 (S参数分析,TDR) 和使用20 MeV的LEHIPA质子束进行实验试验.
主要成果:
- 模拟预测了运行带宽大约为9 GHz.
- 实验室测试证实测量的带宽约为6GHz,与模拟结果一致.
- 使用LEHIPA光束进行实验验证,证明了有效的射频噪声隔离,强大的信号水平,以及~100 ps束结构的准确分辨率.
- 此外,C-WCM的设计还可以实现高性能光束位置监控.
结论:
- 开发的C-WCM是用于加速器应用的经过验证,紧的诊断工具.
- 它成功地集成了高保真度束长度和宽光圈位置监控.
- 这种多功能设备为加速器运行和光束动力学研究提供了显著的优势.
更多相关视频
09:49An Experimental Protocol for Femtosecond NIR/UV - XUV Pump-Probe Experiments with Free-Electron Lasers
Published on: October 23, 2018
16.4K
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
27.5K
相关概念视频
Controlled-Current Coulometry: Overview
640
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
640
Energy Stored In A Coaxial Cable
2.0K
A coaxial cable consists of a central copper conductor used for transmitting signals, followed by an insulator shield, a metallic braided mesh that prevents signal interference, and a plastic layer that encases the entire assembly.
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field inside...
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field inside...
2.0K