通过放射治疗备份和恢复仪表板工具提高网络攻击的弹性
Justin Pijanowski1, Eric Nguyen1, Yasin Abdulkadir1
1Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California, USA.
Journal of applied clinical medical physics
|October 23, 2025
概括
放射性瘤科现在可以在网络攻击后更快地恢复患者治疗,使用新的放射治疗备份和恢复仪表板工具 (RBRDT). 该软件确保了关键处理数据的备份和可访问性,提高了网络攻击的弹性.
科学领域:
- 医学物理 医学物理
- 辐射瘤学 辐射瘤学
- 医疗信息学 医疗信息学
背景情况:
- 网络攻击对放射性瘤科部门构成重大风险,破坏了对关键患者数据和治疗系统的访问.
- 无法访问记录和验证 (R&V) 系统和数据备份,阻碍了患者及时恢复放射治疗.
研究的目的:
- 引入一种新的软件工具,旨在备份放射治疗治疗数据,并为关键患者信息提供可访问的仪表板.
- 描述实施,挑战,并共享开源代码,用于提高辐射瘤诊所网络攻击弹性工具.
主要方法:
- 放射疗法备份和恢复仪表板工具 (RBRDT) 将从R&V和治疗计划系统 (TPS) 的治疗信息和DICOM-RT对象备份到RT-PACS.
- 在R&V系统无法访问的情况下,RBRDT利用RT-PACS的备份数据生成一个仪表板,其中包含正在进行放射治疗的患者的基本治疗细节.
主要成果:
- 在临床环境中,RBRDT已经成功实施,每10分钟执行一次备份.
- 自2024年5月以来,超过8万个RTRECORDS,322个RTPLANS和142个RTSTRUCTS已经被备份到RT-PACS中.
- 仪表板每晚生成一次,提供易于访问的患者治疗信息.
结论:
- 该RBRDT解决了对强大的放射治疗数据备份和恢复解决方案的关键需求.
- 通过将关系数据传输到可访问的RT-PACS,该工具可以减少在网络攻击期间对R&V系统的依赖.
- 通过通过直观的仪表板,RBRDT通过整合和呈现关键数据来促进患者治疗的快速恢复.
相关概念视频
Radiation: Applications
1.7K
The average temperature of Earth is the subject of much current discussion. Earth is in radiative contact with both the Sun and dark space; it receives almost all its energy from the radiation of the Sun and reflects some of it into outer space. Dark space is very cold, about 3 K, so Earth radiates energy into it. For instance, heat transfer occurs from soil and grasses, the rate of which can be so rapid that frost can occur on clear summer evenings, even in warm latitudes.
The average...
The average...
1.7K
Distribution Reliability and Automation
495
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
495
Radial System Protection
418
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
418
Guidelines and Strategies for Safe Computer Charting
2.7K
The guidelines and strategies provided by the American Nurses Association (ANA) and the Canadian Nurses Association (CNA) offer essential principles for ensuring safe and secure computer charting systems in healthcare settings. Let's break down each recommendation:
Maintain Confidentiality and Security:
Maintain Confidentiality and Security:
2.7K
Other Unique Bacteria
412
Magnetic bacteria exhibit a directed movement called magnetotaxis, driven by structures called magnetosomes. These magnetosomes consist of chains of magnetic particles made of either magnetite (Fe₃O₄) or greigite (Fe₃S₄) and are organized in a linear conformation by a protein scaffold within invaginations of the cell membrane. The bacteria align along the north–south magnetic field lines, much like a compass needle. They are typically microaerophilic or anaerobic...
412
Reclosers and Fuses
452
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
452