使用主动反控制提高泡的声吸收系数
Prashant Nayak1, Santosh B Noronha2, Sripriya Ramamoorthy3
1Center for Research in Nanotechnology and Sciences, Indian Institute of Technology Bombay, Mumbai, India.
The Journal of the Acoustical Society of America
|October 24, 2025
概括
这项研究通过使用主动反控制来增强泡中低频声音的吸收. 该方法通过创建零声压边界条件来实现显著增加吸收系数 (AC).
科学领域:
- 声学 声学 在声学方面
- 材料科学 材料科学 材料科学
- 控制工程 控制工程 控制工程
背景情况:
- 泡中低频声音的吸收受限于超过泡厚度的声波长.
- 传统的泡材料在较低频率时具有较低的吸收系数 (AC).
- 需要积极的控制策略来克服固有的材料限制.
研究的目的:
- 增加泡样本的低频吸收系数 (AC).
- 实施一个主动反控制系统,以提高声吸收.
- 分析拟议控制战略的有效性和潜在机制.
主要方法:
- 在阻抗管设置中实现的主动反控制.
- 使用扬声器和麦克风实现的零声压边界条件.
- 控制器设计的频域循环成形方法.
- 实验确定和建模植物转移函数.
主要成果:
- 在200-400Hz范围内,AC从大约0.4到0.7显著增加.
- 开发了一个单维模型来分析控制策略和压力场泄漏.
- 了解了扬声器-麦克风压力场泄漏对交流电的影响.
结论:
- 活动反控制有效地提高了泡中低频声音的吸收.
- 拟议的方法克服了低频率被动泡吸收的局限性.
- 该研究提供了一种可行的方法来提高泡材料的声学性能.
相关概念视频
Effects of feedback
991
Feedback in control systems plays a critical role in shaping various operational parameters, extending beyond simple error reduction to influence stability, bandwidth, gain, impedance, and sensitivity. Understanding these effects requires examining a basic feedback system characterized by defined input, output, error, and feedback signals.
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
991
Feedback control systems
685
Feedback control systems are categorized in various ways based on their design, analysis, and signal types.
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
685
Types of Damping
7.5K
If the amount of damping in a system is gradually increased, the period and frequency start to become affected because damping opposes, and hence slows, the back and forth motion (the net force is smaller in both directions). If there is a very large amount of damping, the system does not even oscillate; instead, it slowly moves toward equilibrium. In brief, an overdamped system moves slowly towards equilibrium, whereas an underdamped system moves quickly to equilibrium but will oscillate about...
7.5K
Damped Oscillations
6.8K
In the real world, oscillations seldom follow true simple harmonic motion. A system that continues its motion indefinitely without losing its amplitude is termed undamped. However, friction of some sort usually dampens the motion, so it fades away or needs more force to continue. For example, a guitar string stops oscillating a few seconds after being plucked. Similarly, one must continually push a swing to keep a child swinging on a playground.
Although friction and other non-conservative...
Although friction and other non-conservative...
6.8K
Effects of Air-entrainment in Concrete
367
Air entrainment in concrete significantly enhances the material's durability, especially in environments subjected to freeze-thaw cycles. Introducing small air bubbles into the concrete mix acts as internal voids that accommodate the expansion of water when it freezes, thereby alleviating internal stress and preventing structural cracks. This function is crucial in climates with significant freezing and thawing, as it protects the concrete from repeated stresses that could lead to premature...
367