同时校准和检测多个分析物,以抵消同时存在的调剂和环境波动的影响
Chu Cheng1, Bingyan Jiang1, Hongyu Chen1
1Pen-Tung Sah Institute of Micro-Nano Science & Technology, Xiamen University, Xiamen, 361005, China.
Analytica chimica acta
|October 24, 2025
概括
一个新的多污染物同时校准和检测 (MSCD) 策略准确地检测水污染物. 这种方法克服了环境波动和干扰,为实时水质监测提供了可靠的方法.
科学领域:
- 环境科学 环境科学
- 分析化学 分析化学
- 电化学 电化学 电化学
背景情况:
- 真正的水体含有多种多样的污染物,时间和气候各不相同.
- 同时在现场检测多种污染物对于水质监测至关重要.
- 微分脉冲电压测量 (DPV) 具有潜力,但对环境波动敏感.
研究的目的:
- 制定一个强大的战略,同时检测多种水污染物.
- 在波动的环境条件下解决电化学方法的局限性.
- 提高现场水质分析的准确性和可靠性.
主要方法:
- 提出了一种多污染物同时校准和检测 (MSCD) 策略.
- 开发了电化学传感器和线性回归算法,以减少错误.
- 利用分析物的特征扫描潜力进行检测.
主要成果:
- 通过MSCD的策略,证明了对pH,温度和干扰物质的抗干扰.
- 在指定度范围内精确检测亚酸盐 (NO2-) 和硫酸盐 (SO32-).
- 实际水样中的相对误差小于±7.8%,优于常用方法.
结论:
- 在具有环境波动的复杂矩阵中,MSCD策略显示出出色的反干扰.
- 提供高精度和可重复性,用于同时检测多种污染物.
- 为实时,现场水质评估提供了一个有前途的替代方案.
相关概念视频
Atomic Absorption Spectroscopy: Interference
2.0K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.0K
High-Performance Liquid Chromatography: Types of Detectors
1.5K
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
1.5K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
1.3K
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.3K
Difference from Background: Limit of Detection
8.0K
The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
The LOD indicates the presence or absence...
8.0K
Calibration Curves: Linear Least Squares
4.1K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
4.1K