Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

1.0K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.0K
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

1.5K
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.5K
Atomic Nuclei: Nuclear Relaxation Processes01:23

Atomic Nuclei: Nuclear Relaxation Processes

1.2K
In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis,  the precessing magnetic moments are randomly oriented around the z-axis.
1.2K
Divergence and Curl of Magnetic Field01:26

Divergence and Curl of Magnetic Field

3.9K
The magnetic field due to a volume current distribution given by the Biot–Savart Law can be expressed as follows:
3.9K
Magnetostatic Boundary Conditions01:28

Magnetostatic Boundary Conditions

1.6K
An electric field suffers a discontinuity at a surface charge. Similarly, a magnetic field is discontinuous at a surface current. The perpendicular component of a magnetic field is continuous across the interface of two magnetic mediums. In contrast, its parallel component, perpendicular to the current, is discontinuous by the amount equal to the product of the vacuum permeability and the surface current. Like the scalar potential in electrostatics, the vector potential is also continuous...
1.6K

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Sensitivity of Literature <math><semantics><mrow><msub><mrow><mi>T</mi></mrow> <mrow><mn>1</mn></mrow></msub></mrow> <annotation>$$ {T}_1 $$</annotation></semantics></math> Mapping Methods to the Underlying Magnetization Transfer Parameters.

NMR in biomedicine·2026
Same author

An image-domain deep-learning denoising technique for accelerated parallel brain MRI: prospective clinical evaluation.

Radiology advances·2025
Same author

Contrast-optimized basis functions for self-navigated motion correction in quantitative MRI.

Magnetic resonance in medicine·2025
Same author

FLAMeS: A Robust Deep Learning Model for Automated Multiple Sclerosis Lesion Segmentation.

medRxiv : the preprint server for health sciences·2025
Same author

Magnetization transfer explains most of the T<sub>1</sub> variability in the MRI literature.

Magnetic resonance in medicine·2025
Same author

Initial assessment of PNS safety for interventionalists during image-guided procedures.

Magma (New York, N.Y.)·2025

相关实验视频

Updated: Jan 13, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

20.1K

第一阶空间编码模拟用于在存在强B0和梯度场变化的情况下提高精度.

Radhika Tibrewala1,2,3, Christopher M Collins1,2,3, Michael Mallett4

  • 1Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, USA.

Magnetic resonance in medicine
|October 28, 2025
PubMed
概括

一个新的磁共振成像 (MRI) 模拟框架使用一级近似来准确地模拟强磁场变化. 这种方法提高了对非传统的MRI扫描仪设计的工件预测和计算效率.

关键词:
可访问的MRI可访问的MRI在同质的领域.模拟器模拟器模拟器模拟器空间编码 空间编码

更多相关视频

Mapping Cortical Dynamics Using Simultaneous MEG/EEG and Anatomically-constrained Minimum-norm Estimates: an Auditory Attention Example
08:45

Mapping Cortical Dynamics Using Simultaneous MEG/EEG and Anatomically-constrained Minimum-norm Estimates: an Auditory Attention Example

Published on: October 24, 2012

15.2K
Neuronavigated Focalized Transcranial Direct Current Stimulation Administered During Functional Magnetic Resonance Imaging
09:33

Neuronavigated Focalized Transcranial Direct Current Stimulation Administered During Functional Magnetic Resonance Imaging

Published on: November 15, 2024

2.0K

相关实验视频

Last Updated: Jan 13, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

20.1K
Mapping Cortical Dynamics Using Simultaneous MEG/EEG and Anatomically-constrained Minimum-norm Estimates: an Auditory Attention Example
08:45

Mapping Cortical Dynamics Using Simultaneous MEG/EEG and Anatomically-constrained Minimum-norm Estimates: an Auditory Attention Example

Published on: October 24, 2012

15.2K
Neuronavigated Focalized Transcranial Direct Current Stimulation Administered During Functional Magnetic Resonance Imaging
09:33

Neuronavigated Focalized Transcranial Direct Current Stimulation Administered During Functional Magnetic Resonance Imaging

Published on: November 15, 2024

2.0K

科学领域:

  • 医学成像物理 医学成像物理
  • 磁共振成像 (MRI) 模拟模拟

背景情况:

  • 低成本和专业的MRI扫描仪经常表现出显著的主磁场 (B0) 的同质性和梯度非线性.
  • 这些场变化挑战了传统MRI模拟器的假设,影响了模拟文物的准确性,例如几何扭曲和信号丢失.

研究的目的:

  • 为具有强烈磁场变化的MRI系统开发一个准确和高效的模拟框架.
  • 为了捕捉字段在同质性和非线性方面的编码效应.
  • 为了能够评估诸如几何扭曲,信号丢失和折叠等工件.

主要方法:

  • 扩展的MRI信号模拟从第0阶 (断片式恒定场) 到第1阶近似 (断片式线性场) 在每个空间网点.
  • 通过在每个网格立方体上进行分析集成来解决MR信号方程,假设线性场变化.
  • 为各种脉冲序列提供了分析积分.

主要成果:

  • 一级近似准确地捕捉了强烈的场变化和相关的intravoxel脱相.
  • 这种方法避免了在0级模拟中常见的严重"响声"工件.
  • 在显著粗的网格上启用模拟,提高计算可行性.

结论:

  • 开发的第一级MRI模拟器有效评估具有强烈磁场变化的非传统扫描仪设计.
  • 该框架提高了MRI模拟在具有挑战性的现场环境中的准确性和效率.