刀片涂层Mo1.33CTxi-MXene电极在水性电解质中的伪电容性行为
Alexey Tsyganov1, Olga Grapenko2, Evgeniy Korotaev3
1Department of Chemistry and Technology of Materials, Yuri Gagarin State Technical University of Saratov, 77 Polytecnicheskaya Street, 410054 Saratov, Russia.
Nanomaterials (Basel, Switzerland)
|October 28, 2025
概括
这项研究介绍了可扩展制造的碳化 (Mo1.33CTx) MXene/碳纳米管 (CNT) 电极用于储能. 电极在各种电解质中表现出高容量,为先进的超级电容器铺平了道路.
科学领域:
- 材料科学 材料科学 材料科学
- 电化学 电化学 电化学
- 纳米技术纳米技术
背景情况:
- 二维碳化物 (Mo1.33CTx) MXene显示了电化学能量储存的希望.
- 高缺陷性和Mo1.33CTx的聚合阻碍了大规模的电极制造.
研究的目的:
- 开发可扩展的Mo1.33CTx/碳纳米管 (CNT) 电极的制造.
- 为了评估这些电极在各种电解质中的电化学性能.
主要方法:
- 可扩展的医生刀片技术用于电极制造.
- 使用循环电压测量和静电电荷放电的电化学表征.
- 在H2SO4,H3PO4,LiCl和KCl电解质中进行测试.
主要成果:
- 在1.6mg/cm2负载下实现的352F/g (在H2SO4) 的特定容量.
- 即使在增加质量负载 (3.5 mg/cm2) 时,也保持了高容量.
- CNTs促进了快速的离子传输,确保了高扫描速率的高容量.
结论:
- 可以进行可扩展的Mo1.33CTx/CNT电极制造.
- 这些电极为超级电容器应用提供了高性能.
- 这项研究为开发先进的电极材料开辟了道路.
相关概念视频
Potentiometry: Membrane Electrodes
1.6K
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
1.6K
Dielectric Polarization in a Capacitor
5.9K
The presence of a dielectric medium in a capacitor not only changes the voltage and capacitance but also affects the electric field. In general, dielectrics can be of two types: polar and nonpolar. In a polar dielectric, the positive and negative charges in the molecules are separated by a distance and hence have a permanent dipole moment. In contrast, no such charge separation exists in a nonpolar dielectric, however the nonpolar molecules get polarized in the presence of an external electric...
5.9K
Potentiometry: Types of Electrodes
1.9K
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
1.9K
Controlled-Potential Coulometry: Electrolytic Methods
660
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
The chosen potential...
660