相关实验视频
Updated: Jan 13, 2026

10:49
Planar and Three-Dimensional Printing of Conductive Inks
Published on: December 9, 2011
37.7K
基于导电性PLA材料的三维打印温度传感器
Agnese Staffa1, Gašper Krivic2, Mariachiara Tocci1
1Department of Engineering, University of Perugia, Via Goffredo Duranti 93, 06125 Perugia, Italy.
Sensors (Basel, Switzerland)
|October 29, 2025
概括
研究人员开发了一个3D打印的温度传感器,使用导电性PLA光纤. 这种创新的传感器显示电阻和温度之间的可靠相关性,使得印刷结构中的热监测能够准确.
科学领域:
- 材料科学 材料科学 材料科学
- 增材制造 增材制造 增材制造
- 传感器技术 传感器技术
背景情况:
- 热塑性挤出3D打印技术的进步使导电复合材料等功能性材料成为可能.
- 导电复合材料为将传感器直接集成到3D打印结构铺平了道路.
研究的目的:
- 为了研究使用商业导电性PLA灯丝用于3D打印温度传感器的可行性.
- 分析3D打印样本中的电阻和温度之间的关系.
主要方法:
- 在用导电性PLA制成的3D打印样本上进行实验.
- 分析电阻与温度之间的相关性.
- 从电阻测量得出一个用于估计温度的函数.
主要成果:
- 在电阻和温度之间发现了明确和可重现的关系.
- 一个基于电阻的温度估计函数被成功推导出来.
结论:
- 导电性PLA是一种可行的,低成本的材料,用于创建集成温度传感器.
- 这项工作推进了通过增材制造用于热监测的功能传感器的集成.
相关概念视频
Equipments Used to Measure Body Temperature
1.7K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.7K
Assessing Body Temperature - Oral
1.4K
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
1.4K