测量系统和测试程序用于对Rogowski线圈的电压到电压和电压到电流集成电路的转换精度进行表征
1Institute of Mechatronics and Information Systems, Lodz University of Technology, 90-537 Lodz, Poland.
Sensors (Basel, Switzerland)
|October 29, 2025
概括
这项研究引入了一种用于测试Rogowski线圈信号调节器的新方法. 这种新的方法准确地描述了活跃集成器,提高了电力计量精度.
科学领域:
- 电气工程 电气工程
- 计量学 计量学 计量学
背景情况:
- 罗戈夫斯基线圈对于电力计量至关重要,但需要主动集成电路来准确测量电流.
- 信号调节器的准确性显著影响了传感器的整体性能.
研究的目的:
- 提出一种新的测量系统和测试程序,用于描述与罗格斯基线圈使用的活性集成器.
- 为了能够在扭曲条件下评估压向电压和压向电流转换器的转换精度.
主要方法:
- 使用数字功率计和任意波形发生器进行了新型测试程序.
- 复制了Rogowski线圈输出电压与波形发生器来测试主动集成器.
- 对于扭曲的输入电压和声波和跨频率的相位转移,确定了转换误差.
主要成果:
- 新系统有效地描述了活跃集成器的转换精度.
- 对各种序和频率进行了量化转换误差和相位移.
- 任意波形发生器方法克服了与直接Rogowski线圈信号测试相关的挑战.
结论:
- 拟议的测量系统为评估Rogowski线圈信号调节器性能提供了一种可靠的方法.
- 准确地描述活跃集成器对于提高电力计量精度至关重要.
- 这种方法有助于开发更准确的电力测量系统.
更多相关视频
10:36Advanced Experimental Methods for Low-temperature Magnetotransport Measurement of Novel Materials
Published on: January 21, 2016
11.0K
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
6.2K
相关概念视频
Galvanometer
2.8K
Common devices, including car instrument panels, battery chargers, and inexpensive electrical instruments, measure potential difference (voltage), current, or resistance using a d'Arsonval galvanometer. This electromechanical instrument is also known as a moving coil galvanometer.
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
2.8K
Potentiometer
1.8K
Voltage and current measurements using a standard voltmeter and ammeter alter the circuit being measured either by drawing or resisting the current flow, which introduces uncertainties in the measurements. Null measurements balance the voltages so that no current flows through the measuring device and, therefore, no alterations occur in the measured circuit.
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...
1.8K
Uncertainty in Measurement: Reading Instruments
50.1K
Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...
50.1K
Voltmeter
2.5K
A voltmeter is an electrical device that measures the potential difference or voltage between two points. It is connected in parallel with the circuit element it is measuring. A parallel connection is used because elements in parallel experience the same potential difference. The voltmeter is represented by the symbol "V ".
An ideal voltmeter would have infinite resistance, so connecting it between two points in a circuit would not alter any of the currents. Real voltmeters always have...
An ideal voltmeter would have infinite resistance, so connecting it between two points in a circuit would not alter any of the currents. Real voltmeters always have...
2.5K
Voltammetry: Factors Affecting Measurements
513
A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
513
Equivalent Circuits for Practical Transformers
1.4K
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
1.4K