在溶剂提取后,对产品放射性核化物溶液中的有机污染物进行评估,并随后使用微柱进行其去除
Svenja Trapp1, Brenda Giling1, Esmee Spuijbroek1
1Department of Radiation Science and Technology, Delft University of Technology, Delft, 2629 JB, The Netherlands.
概括
溶剂提取中的污染物,如BPHA和DIZ,可以阻碍放射性标记. 一种新的微柱净化方法有效地从Ga-68溶液中去除这些污染物,提高了放射性标记的效率.
科学领域:
- 放射化学 放射化学是指辐射化学.
- 核医学就是核医学.
- 分析化学 分析化学
背景情况:
- 医学放射性核酸 (例如Ga-68) 对于诊断和治疗至关重要.
- 目前的分离方法,如离子交换色谱法是标准的.
- 微流体溶剂提取是一种新兴的放射性核素分离技术.
研究的目的:
- 调查溶剂提取过程中化剂污染对放射性核素放射性标记的影响.
- 开发和评估放射性核素溶液的微柱净化方法.
主要方法:
- 作为潜在的污染物,研究了N-基-N-基胺 (BPHA),迪西 (DIZ) 和二-2-乙) 酸 (D2EHPA).
- 评估了这些污染物对DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) 标签的干扰.
- 开发并应用了Ga-68溶液的微柱净化方法.
主要成果:
- 污染的BPHA和DIZ显著干扰了DOTA标签.
- 微柱净化方法完全消除了Ga-68.8的BPHA污染.
- 净化方法还减少了溶液体积和酸度.
结论:
- 化剂污染是基于溶剂提取的放射性核素分离的一个关键问题.
- 微柱净化是一种有效的策略,可以去除污染物并改善放射性标记.
- 这种方法显示了将其集成到用于放射性核素生产的自动化微流体系统中的希望.
更多相关视频
13:16A Whole Cell Bioreporter Approach to Assess Transport and Bioavailability of Organic Contaminants in Water Unsaturated Systems
Published on: December 24, 2014
10.9K
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
1.2K
相关概念视频
Extraction: Advanced Methods
1.1K
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
1.1K
Ion-Exchange Chromatography
1.8K
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
1.8K
Principles Of Column Chromatography
8.5K
The chromatography technique was first invented in 1901 by Michael S. Tswett, a Russian botanist, to separate plant pigments using organic solvents. Further, in 1941, Archer John Porter Martin and R. L. M. Synge modified the technique by packing silica gel into a column. A mixture of amino acids was then separated on the packed column using chloroform and water mixture as the mobile phase. This was the first report on column chromatography. At present, column chromatography is a widely used...
8.5K
Types Of Column Chromatography
13.2K
The stability and compatibility of column material with samples are crucial for efficient purification in chromatographic techniques. Various operating parameters such as pH, temperature, or solvent affect the packing of the column material, thereby determining the purification efficiency. The choice of column material also plays an essential role in deciding the operating parameters and can be modified based on the proteins that need to be purified.
Gel Filtration Chromatography
When the...
Gel Filtration Chromatography
When the...
13.2K