Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Design Example: Vintage Mixing Console01:17

Design Example: Vintage Mixing Console

540
A sound engineer at a music company recently encountered a problem. The output from their newly acquired studio's vintage mixing console was too low for the requirements of modern recording equipment. To rectify this situation, the engineer decided to design an audio pre-amplifier using an operational amplifier (op-amp) to boost the signal level.
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
540
Upsampling01:22

Upsampling

573
Managing signal sampling rates is essential in digital signal processing to maintain signal integrity. A decimated signal, characterized by a reduced frequency range due to its lower sampling rate, can be upsampled by inserting zeros between each sample. This upsampling process expands the original spectrum and introduces repeated spectral replicas at intervals dictated by the new Nyquist frequency. To refine this zero-inserted sequence, it is passed through a lowpass filter with a cutoff...
573
Design Example01:23

Design Example

525
The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
525
The Y-to-Delta Circuit01:19

The Y-to-Delta Circuit

680
A balanced wye-to-delta circuit comprises balanced Y-connected voltage sources and delta-connected loads with no neutral line connection.
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
680
Cascaded Op Amps01:16

Cascaded Op Amps

1.1K
Operational amplifiers (op-amps) are versatile electronic components that can be interconnected in a cascade - one after another in a linear sequence. This cascading is possible due to their infinite input resistance and zero output resistance, allowing them to maintain their input-output relationships even when connected in series.
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
1.1K
Downsampling01:20

Downsampling

594
When considering a sampled sequence with zero values between sampling instants, one can replace it by taking every N-th value of the sequence. At these integer multiples of N, the original and sampled sequences coincide. This process, known as decimation, involves extracting every N-th sample from a sequence, thereby creating a more efficient sequence.
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
594

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Current CMC challenges in oligonucleotide API development: from IND to NDA.

Medicinal chemistry research : an international journal for rapid communications on design and mechanisms of action of biologically active agents·2026
Same author

Reversible coma and elevated central venous pressure: warning signs of acute superior vena cava graft thrombosis following Warden procedure: a case report.

BMC anesthesiology·2026
Same author

SRSF1/Mcl-1 Axis Drives Apoptosis Evasion and Shapes the Immune Microenvironment to Promote Gastric Cancer Progression.

Human mutation·2026
Same author

Application and Molecular Modification of Enzyme in Textile Degumming.

Applied biochemistry and biotechnology·2026
Same author

Nonlinear compensation using a robust neural network for noisy samples in a high-speed coherent optical transceiver.

Optics express·2026
Same author

Triple-valve replacement in repaired tetralogy of fallot patients with mirror-image dextrocardia: a case report.

Journal of cardiothoracic surgery·2026

相关实验视频

Updated: Jan 12, 2026

Studying Cavitation Enhanced Therapy
07:36

Studying Cavitation Enhanced Therapy

Published on: April 9, 2021

5.7K

基于低分辨率DAC的预等分系统的通道响应感知型三极形模拟器设计.

Linsheng Zhong, Yuming Zhao, Sunningchang Zhang

    Optics letters
    |November 4, 2025
    PubMed
    概括

    我们开发了一种通道响应感知型三角形信号调制器 (CRA-DSM),可以提高数字对模拟转换器预等级的信号噪声比. 这种自适应技术可以在没有额外的硬件的情况下增强带宽有限的移动前程系统.

    科学领域:

    • 电气工程 电气工程
    • 信号处理 信号处理
    • 电信 电信服务 电信服务 电信服务

    背景情况:

    • 数字对模拟转换器 (DAC) 中的预等分系统对于提高信号质量至关重要.
    • 传统的三角信号调制器 (DSM) 缺乏适应道特征的适应性.
    • 带宽有限的移动前程系统需要高效的信号处理解决方案.

    研究的目的:

    • 提出和演示一种新的通道响应意识的三角形信号调制器 (CRA-DSM).
    • 为了优化CRA-DSM,使用基因算法进行低分辨率DAC预等级.
    • 通过适应性塑造噪声以匹配频道响应来增强信号噪声比 (SNR).

    主要方法:

    • 开发了一种优化CRA-DSM的遗传算法.
    • 实现基于频道频率响应的适应性噪声塑造.
    • 在不同的频道上实验性地传输了高速数据信号 (32 Gb/s 16-QAM DMT和15.2 Gb/s 16-QAM OFDM).

    主要成果:

    • CRA-DSM实现了适应式噪声分布,与频道频率响应相匹配.
    • 证明了显著的SNR增益:在低通道中1.6dB,在5.5GHz带通道中1.2dB.
    • 在两种实验场景中表现优于传统的DSM.

    更多相关视频

    Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
    09:01

    Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques

    Published on: April 4, 2017

    9.1K
    X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
    08:30

    X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

    Published on: September 11, 2011

    14.8K

    相关实验视频

    Last Updated: Jan 12, 2026

    Studying Cavitation Enhanced Therapy
    07:36

    Studying Cavitation Enhanced Therapy

    Published on: April 9, 2021

    5.7K
    Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
    09:01

    Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques

    Published on: April 4, 2017

    9.1K
    X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
    08:30

    X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

    Published on: September 11, 2011

    14.8K

    结论:

    • 在没有额外的硬件复杂性的情况下,CRA-DSM有效地改善了SNR.
    • 拟议的CRA-DSM是带宽有限的移动前航系统的实际解决方案.
    • 遗传算法优化可以提高DSM在预等值应用中的性能.