在具有多个操作约束的网络物理微电网中分布式二次频率合作和电力分配
IEEE transactions on cybernetics
|November 4, 2025
概括
这项研究通过使用一种新的分布式控制方法来提高交流微电网的稳定性和可靠性. 它确保在波动负载下进行频率调节和功率分配,提高系统的稳定性.
科学领域:
- 电气工程 电气工程
- 控制系统 控制系统
- 网络化系统 网络化系统
背景情况:
- 在动态负载条件下,交流微电网需要强大的频率调节和功率分配.
- 现有的控制策略往往在暂时稳定性和网络物理合方面扎.
研究的目的:
- 为了研究落控制的交流微电网,对短暂稳定性的关键约束.
- 开发一种新的基于通信网络的二次分布式控制方法.
- 为了保证有限的输入-输出稳定性,以改善主动功率分配.
主要方法:
- 将库拉莫托振荡器模型集成到初级控制规律中.
- 开发一种考虑各种物理节点特征的二次分布式控制.
- 适用不变量理论和非二次的利亚普诺夫技术.
主要成果:
- 足够和必要的条件,以提高系统在负载波动下的稳定性和可靠性.
- 为交流微电网建立网络物理合动态.
- 在特定条件下保证了有限的输入-输出稳定性.
结论:
- 拟议的控制方法显著提高了交流微电网的稳定性和可靠性.
- 通过对各种电力系统的数值案例研究来验证这些发现.
- 这项工作为微电网应用中的先进控制策略提供了基础.
更多相关视频
05:30Large Scale Energy Efficient Sensor Network Routing Using a Quantum Processor Unit
Published on: September 8, 2023
1.1K
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
6.2K
相关概念视频
Fast Decoupled and DC Powerflow
724
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
724
Load-frequency control
608
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
608
Secondary Distribution
541
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
541
Maximum Power Flow and Line Loadability
581
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
581
Multimachine Stability
539
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
539
Power System Distribution
1.0K
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
1.0K