跨大陆的非标准电网频率统计数据
Xinyi Wen1, Mehrnaz Anvari2, Leonardo Rydin Gorjão3,4
1Institute for Automation and Applied Informatics (IAI), Karlsruhe Institute of Technology (KIT), 76344, Karlsruhe, Germany.
Scientific reports
|November 4, 2025
概括
本研究分析了来自不同地区的电网频率数据,揭示了独特的统计属性. 这些发现有助于为电网稳定性和性能评估创建更准确的模型.
科学领域:
- 电气工程 电气工程
- 复杂系统分析 复杂系统分析
- 统计物理 统计物理
背景情况:
- 电网频率是电力供需平衡和电网稳定的关键指标.
- 之前对电网频率的分析在地理上是有限的,缺乏定量深度.
- 了解频率变化对于评估预测模型和合成电网频率数据至关重要.
研究的目的:
- 分析和量化电网频率数据的统计和随机属性.
- 在实证和合成频率数据中识别非标准的统计特征.
- 开发用于基准测试模型和特征实证电网频率数据的工具.
主要方法:
- 来自亚洲,澳大利亚和欧洲同步区域的自记录电网频率数据的分析.
- 高分辨率数据采样,每隔一秒.
- 统计和随机属性的量化.
主要成果:
- 在不同地区的电网频率数据中识别非标准的统计属性.
- 证明这些属性如何限制可能的随机电网频率模型.
- 开发和共享用于模型基准测试和数据表征的分析工具.
结论:
- 电网频率表现出复杂的统计行为,需要广泛的地理分析.
- 这些发现为开发更准确,更普遍的电网频率模型提供了框架.
- 进一步的研究应集中在不同的同步领域,以确保模型的稳定性.
相关概念视频
Load-frequency control
608
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
608
Secondary Distribution
541
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
541
Average Power
1.0K
In practical electrical applications, the concept of time-varying instantaneous power is not frequently utilized. Instead, focus shifts to the more practical quantity known as average power. Average power is determined by integrating the instantaneous power over a specified time period and subsequently dividing it by that duration.
1.0K
The Power Superposition Principle
386
Consider a circuit with two sinusoidal voltage sources. Each one influences the circuit independently, and the superposition principle helps us understand the combined effect by adding up the responses from each source.
386
Electrical Power
3.6K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.6K
Conservation of AC Power
639
The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
639