Seong Tak Woo1

  • 1Department of Electronic Engineering, Dong Seoul University, Seongnam, 13117, Republic of Korea. stwoo@du.ac.kr.

Scientific reports
|November 5, 2025
PubMed
概括

电阻相角变化与健康成年人的舌接触强度相关. 这一发现表明阻抗相角可以客观地测量发音,并帮助诊断语音障碍.

相关概念视频

RLC Series Circuits: Impedance01:29

RLC Series Circuits: Impedance

When current flow is opposed in a DC or AC circuit, it is referred to as resistance or impedance, respectively. Impedance plays a key role in determining the performance of AC circuits. It is represented by Z, which is a combination of resistance and reactance, and depends upon the angular frequency, measured in ohms.
Thus, the magnitude of the impedance is given by the following equation,
2.5K
Impedances and Admittance01:23

Impedances and Admittance

In the realm of AC circuits, passive circuit elements like resistors, inductors, and capacitors take on a different character when characterized by phasor voltage and current. Their behavior is expressed through impedance, a vital concept in AC circuit analysis.
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
1.8K
Series Impedances: Three-Phase Line01:27

Series Impedances: Three-Phase Line

Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
415
Bode Plots Construction01:24

Bode Plots Construction

The Bode plot is an essential tool in control system analysis, mapping the frequency response of a system through a magnitude plot and a phase plot, both against a logarithmic frequency axis. To construct a Bode plot, consider the transfer function H(ω):
1.1K
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
392
Interference: Path Lengths01:10

Interference: Path Lengths

Consider two sources of sound, that may or may not be in phase, emitting waves at a single frequency, and consider the frequencies to be the same.
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
1.8K