用不同的设备测量脉冲振荡计参数的差异
Chalerm Liwsrisakun1, Athavudh Deesomchok1, Chaicharn Pothirat1
1Profs. Liwsrisakun, Deesomchok, Pothirat, Ms. Duangjit, and Dr. Chaiwong are affiliated with Division of Pulmonary, Critical Care, and Allergy, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.
Respiratory care
|November 10, 2025
概括
脉冲振荡计 (IOS) 对反应强度,共振频率 (Fres) 和反应强度曲线下的面积 (AX) 的测量在MasterScreen-IOS和MostGraph-02设备之间存在显著差异. 这些差异意味着IOS结果不能用于跟踪肺病进展.
科学领域:
- 肺功能测试试验 肺功能测试
- 呼吸系统生理学 呼吸系统生理学
- 医疗设备比较 医疗设备比较
背景情况:
- 在不同设备的绝对和百分比预测脉冲振荡计 (IOS) 值上存在有限的数据.
- 了解设备特定的IOS性能对于慢性呼吸道疾病的准确解释至关重要.
研究的目的:
- 在MasterScreen-IOS和MostGraph-02设备之间比较脉冲振荡计 (IOS) 值和百分比预测值.
- 评估COPD和喘患者的两种不同设备获得的IOS测量的一致性和相关性.
主要方法:
- 使用MasterScreen-IOS和MostGraph-02.2对54名受试者 (喘和COPD) 的IOS数据进行了回顾性分析.
- 为了比较IOS值,使用了对的样本t测试和Pearson的相关性.
- 布兰德-阿尔特曼分析确定了两种设备之间的一致性极限.
主要成果:
- 在两个设备之间的绝对和百分比预测反应强度值,包括共振频率 (Fres) 和反应强度曲线 (AX) 下的面积 (AX) 中观察到显著差异.
- 与MostGraph-02.2相比,MasterScreen-IOS产生了更高的反应强度值.
- 在抵抗异质性 (R5-R20),Fres和AX的百分比预测值中发现了差异.
结论:
- 在MasterScreen-IOS和MostGraph-02设备之间存在显著的IOS反应率值差异.
- 设备特定的参考方程可能会导致预测值百分比的变化.
- 这些设备的IOS测量应谨慎解释,并且不能用于纵向评估.
相关概念视频
Special considerations while measuring pulse
891
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
891
Pulse Oximetry
1.2K
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.2K
Voltammetry: Factors Affecting Measurements
507
A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
507
Equipments Used To Measure Blood Pressure
3.0K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.0K