预测模型和实验研究的空间频率中误差在外轴无球X射线镜头的盖帽抛光的外轴无球X射线镜头
Optics express
|November 11, 2025
概括
帽子抛光会在超精密光学上产生中空间频率 (MSF) 错误. 这项研究开发了一个MSF错误的预测模型,显示它们随着更高的速度比率和更小的步骤间隔而减少.
科学领域:
- 超精确的光学制造超精确的光学制造
- 表面计量学 表面计量学
- 亚球光学制造业 制造亚球光学
背景情况:
- 帽子抛光是一种用于高精度光学元件的亚光圈技术.
- 中位空间频率 (MSF) 错误会降低光学性能.
- 了解MSF错误生成对于流程优化至关重要.
研究的目的:
- 为了调查MSF在外轴无球X射线镜头的盖帽抛光过程中的错误形成.
- 建立一个预测模型,将过程参数与MSF错误联系起来.
- 通过实验验证预测模型,并确定减少错误的关键参数.
主要方法:
- 分析盖帽抛光接触区的几何,接触压力和运动速度.
- 基于工具路径参数的MSF错误预测模型的开发.
- 实验验证使用拉斯特抛光,具有不同的速度比和步骤间隔.
主要成果:
- 为MSF错误开发了一个预测模型,并经过实验验证.
- 发现MSF错误随着速度比的增加而减少.
- 此外,MSF错误也发现,随着拉斯特抛光的步骤间隔的减少,MSF错误也会减少.
- 该模型预测了MSF错误,与实验数据最大偏差为12.37%.
结论:
- 开发的模型提供了一种实际的方法,用于预测和抑制MSF在机顶抛光中的错误.
- 优化速度比和步间是最大限度地减少MSF错误的关键策略.
- 这项研究有助于提高使用盖帽抛光制造的超精密光学产品的表面质量.
更多相关视频
12:14The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry
Published on: August 12, 2013
22.4K
09:01Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
Published on: April 4, 2017
9.0K
相关概念视频
Uncertainty in Measurement: Accuracy and Precision
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.
Space-Time Curvature and the General Theory of Relativity
In 1905, Albert Einstein published his special theory of relativity. According to this theory, no matter in the universe can attain a speed greater than the speed of light in a vacuum, which thus serves as the speed limit of the universe.
This has been verified in many experiments. However, space and time are no longer absolute. Two observers moving relative to one another do not agree on the length of objects or the passage of time. The mechanics of objects based on Newton's laws of motion,...
This has been verified in many experiments. However, space and time are no longer absolute. Two observers moving relative to one another do not agree on the length of objects or the passage of time. The mechanics of objects based on Newton's laws of motion,...
NMR Spectrometers: Resolution and Error Correction
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
Random Error
Random or indeterminate errors originate from various uncontrollable variables, such as variations in environmental conditions, instrument imperfections, or the inherent variability of the phenomena being measured. Usually, these errors cannot be predicted, estimated, or characterized because their direction and magnitude often vary in magnitude and direction even during consecutive measurements. As a result, they are difficult to eliminate. However, the aggregate effect of these errors can be...
Common Leveling Mistakes and Errors
A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...