Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Computed Tomography01:10

Computed Tomography

7.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
7.6K

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Development and validation of a machine learning model for sperm DNA fragmentation rate in infertile men: a multicenter retrospective study.

Frontiers in endocrinology·2026
Same author

RNF114-PACSIN3 signaling axis promotes hepatocellular carcinoma progression by enhancing GLUT1 membrane retention and glucose uptake.

Cellular oncology (Dordrecht, Netherlands)·2026
Same author

Does adherence to Canadian 24-Hour Movement Guidelines reduce all-cause mortality in patients with chronic kidney disease?

Medicine·2026
Same author

Sequential Release From Hierarchical MOF-on-MOF Architectures for Programmable Self-Healing and Self-Warning Coatings.

Small (Weinheim an der Bergstrasse, Germany)·2026
Same author

EGFR-dependent delivery of phosphorylated IGFBP3 by cancer stem cells drives chemotherapy resistance in colorectal cancer.

Cell death & disease·2026
Same author

[Mechanism of electroacupuncture at sensitized "Sanyinjiao" (SP6) in alleviating primary dysmenorrhea in rats based on Piezo1 ion channel].

Zhen ci yan jiu = Acupuncture research·2026

相关实验视频

Updated: May 1, 2026

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

8.4K

使用动态重建和运动估计方法进行预先调整的渐进时间解析CBCT重建.

Ruizhi Zuo1, Hua-Chieh Shao1, You Zhang1

  • 1The Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.

Medical physics
|November 11, 2025
PubMed
概括

在DREME-adapt-pro框架允许快速和准确的时间解析圆束CT (CBCT) 重建放射治疗. 这种方法显著提高了运动跟踪的准确性,并减少了重建时间,提高了临床采用.

关键词:
精细调节 精细调节 精细调节图像重建 图像重建运动估计运动估计运动模型 运动模型时间解析的动态CBCT.

更多相关视频

Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
06:56

Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation

Published on: January 7, 2021

2.8K
Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
10:44

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

Published on: June 21, 2024

1.0K

相关实验视频

Last Updated: May 1, 2026

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

8.4K
Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
06:56

Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation

Published on: January 7, 2021

2.8K
Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
10:44

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

Published on: June 21, 2024

1.0K

科学领域:

  • 医疗成像医学成像
  • 放射治疗 物理 物理
  • 计算成像技术的成像

背景情况:

  • 圆束CT (CBCT) 对于放射治疗中的图像指导至关重要,但呼吸诱导的运动使准确的解剖捕捉复杂化.
  • 时间解析的CBCT是追踪空间时间解剖变化的理想方法,但它面临着准确性和效率方面的挑战.

研究的目的:

  • 开发一个快速解决的CBCT重建框架 (DREME-adapt) 以提高准确性和效率.
  • 为了实现动态重建和运动估计,初始化和适应性地根据先前的重建进行条件化.

主要方法:

  • DREME-adapt从分数CBCT扫描中重建时间解析的CBCT序列,创建基于机器学习的运动模型.
  • 它使用"冷启动"虚拟分数用于初始重建和"热启动"用于随后的分数,优化重建速度.
  • 在幻影和患者研究中评估了三个策略 (DREME-cs,DREME-adapt-vfx,DREME-adapt-pro).

主要成果:

  • 在模拟中,DREME-adapt-pro表现出优异的性能,图像重建误差较低 (0.14 ± 0.01) 和瘤质中心跟踪误差 (0.92 ± 0.62 mm).
  • 在患者研究中,DREME-adapt-pro本地化移动肺部地标,平均误差为2.21 ± 1.79毫米.
  • 用于DREME-adapt-pro的训练时间减少到11分钟,是原始DREME算法的15%.

结论:

  • DREME-adapt-pro在机载时间解析的CBCT重建中实现了高效率和准确性.
  • 该框架显著提高了DREME方法用于放射治疗图像指导的临床适用性.