来自果手表和ActiGraph设备的休息活动节奏指标的比较
Gehui Zhang1, Robert T Krafty2, Stephen F Smagula3
1School of Sciences, Southwest Petroleum University, Chengdu, China.
Sleep
|November 11, 2025
概括
像Apple Watch这样的消费者可穿戴设备在测量个人排名的休息活动节奏 (RAR) 中显示出良好的一致性,但绝对值不同,因此它们不应用于临床风险查.
科学领域:
- 生物医学工程 生物医学工程
- 时间生物学 时间生物学
- 可穿戴技术可穿戴技术
背景情况:
- 休息活动节律 (RAR) 障碍与显著的健康结果有关.
- 消费者可穿戴设备为监测RAR提供了一个可扩展的方法,可能有助于临床风险因素查.
研究的目的:
- 评估来自消费者可穿戴设备 (Apple Watch) 和研究级设备 (ActiGraph) 的RAR指标的可比性.
- 评估两种设备类型之间的各种RAR指标的可靠性和一致性.
主要方法:
- 参与者 (n=23) 在一周内同时佩戴Apple Watch和ActiGraph.
- 从加速度计数据中提取了非参数和扩展位元RAR变量.
- 使用斯皮尔曼相关性评估关联,使用类内相关系数 (ICC) 评估一致性/一致性.
主要成果:
- 两种设备的RAR测量高度相关 (斯皮尔曼R:0.7-0.9).
- 对于大多数指标,观察到良好的可靠性 (ICC:0.74-0.85),只有像振幅这样的显著例外.
- 一致性ICC比协议ICC高 (好至优秀范围),表明参与者排名相似,但绝对值不相同.
结论:
- 消费者可穿戴设备在对RAR指标的参与者排名中表现出良好的到优秀的一致性.
- 尽管相关性和一致性很高,但存在系统的分歧,阻止了不同设备的绝对值的组合.
- 可穿戴设备显示可扩展RAR监测的希望,但对于绝对值的直接临床应用需要进一步验证.
相关概念视频
Pulse rhythm
1.3K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.3K
Correlation between ECG and Cardiac Cycle
11.6K
The electrical signals recorded on an electrocardiogram (ECG) occur before the mechanical processes of contraction and relaxation during the cardiac cycle.
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
11.6K