对于模块化固态变压器的减少开关多个主动桥直流-直流转换器.
Saeid Khani1,2, Seyed Hossein Hosseini3,4, Mehran Sabahi5
1East Azarbaijan Electric Power Distribution Company, Tabriz, Iran. saeid_khani82@yahoo.com.
Scientific reports
|November 12, 2025
概括
一种新的减少开关多个主动桥 (RS-MAB) DC-DC转换器提高了固态变压器 (SST) 的效率和功率密度. 扩展三角电流模式 (TCM) 调制确保了软切换,以提高性能.
科学领域:
- 电气工程 电气工程
- 电力电子 电力电子 电力电子
- 可再生能源系统可再生能源系统
背景情况:
- 固态变压器 (SST) 对现代电网至关重要.
- 现有的SST设计经常面临效率和功率密度方面的挑战.
- 减少组件数量是提高SST性能的关键.
研究的目的:
- 引入一种新的减少开关多重活性桥 (RS-MAB) DC-DC转换器拓.
- 提高模块化SSTs的效率和功率密度.
- 为了验证一个新的调制策略,以改善转换器的操作.
主要方法:
- 对RS-MAB转换器结构的理论分析.
- 扩展三角电流模式 (TCM) 调制的开发和应用.
- 数字模拟和实验室规模的实验验证.
主要成果:
- 该RS-MAB转换器大大减少了开关设备和高频变压器.
- 扩展的TCM调制使整个操作范围的软切换成为可能.
- 实验结果证实了拟议的RS-SQAB转换器和调制器的可行性和有效性.
结论:
- 拟议的RS-MAB直流-直流转换器是模块化SST的有效构建块.
- 扩展的TCM调制策略成功实现了软切换并提高了性能.
- 这项研究证实了一种有希望的方法,用于更高效和更紧的SST设计.
更多相关视频
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
10.7K
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
12.1K
相关概念视频
Bridge rectifier
1.4K
The bridge rectifier is essential in electronics for efficiently converting alternating current (AC) to direct current (DC). Comprised of four diodes configured in a bridge layout, this rectifier effectively processes both the positive and negative halves of the AC waveform, making it superior to half-wave and full-wave center-tapped rectifiers in terms of voltage regulation and output stability.
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
1.4K
Equivalent Circuits for Practical Transformers
1.3K
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
1.3K
Energy Losses in Transformers
1.3K
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
1.3K
Types Of Transformers
1.4K
Transformers can provide desired voltages to a circuit by modifying the number of turns in the secondary windings.
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
1.4K
Half wave rectifier
2.4K
A half-wave rectifier is a fundamental circuit in electronics, designed to convert alternating current (AC) voltage into a unidirectional voltage. It utilizes the simplest form of diode rectification, where the circuit comprises a single diode in series with a load resistor and an AC power source.
2.4K
Three-Winding Transformers
667
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
667