实时铁路电气化系统监测:对技术的综述
Jose A Sainz-Aja1, João Pombo2,3,4, Jordan Brant2
1LADICIM (Laboratory of Science and Engineering of Materials), University of Cantabria, 39005 Santander, Spain.
Sensors (Basel, Switzerland)
|November 13, 2025
概括
pantograph-overhead contact line (OCL) 接口的状态监测 (CM) 系统对于铁路安全至关重要. 本综述详细介绍了当前的CM技术,其局限性和未来的趋势,以提高OCL性能并减少延迟.
科学领域:
- 铁路工程 铁路工程是指铁路工程.
- 电气工程 电气工程 电气工程
- 材料科学是一种材料科学.
背景情况:
- pantograph-overhead contact line (OCL) 接口对于电气化铁路至关重要,但容易受到磨损,环境因素和维护问题的影响.
- 这个系统的故障会造成严重的交通干扰和火车延误,每年损失数千小时.
- 不断发展的维护策略强调基于数据的决策支持和先进的传感系统.
研究的目的:
- 提供一个全面的当前状态监控 (CM) 系统的综合审查,用于横流机-OCL接口.
- 分析现有的CM技术的优缺点.
- 概述OCL状况监测的未来趋势和研究方向.
主要方法:
- 对 pantograph-OCL.现有状态监控系统的文献综述.
- 分析系统性能,包括优缺点.
- 识别新兴趋势和技术进步.
主要成果:
- 当前的CM系统在有效性和适用性方面各不相同.
- 主要挑战包括磨损,环境影响和影响性能的维护缺陷.
- 技术进步正在推动实时数据的采用,以改善决策.
结论:
- 状态监测对于提高铁路运营的可靠性,可用性和安全性至关重要.
- 需要进行进一步的研究和开发,以优化CM系统的泛相机-OCL接口.
- 未来的趋势指向集成的,数据驱动的方法,用于主动维护和故障预防.
相关概念视频
Line Protection with Impedance Relays
426
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
426
Overcurrent Relays
472
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
472
Reclosers and Fuses
442
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
442
Differential Relays
711
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
711
Holter Monitor: 24-Hour Monitoring
1.9K
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
1.9K
Pulse rhythm
1.3K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.3K