简单电源质量指数的实验验证,用于高达150 kHz的频率内容评估
Christian Betti1, Roberto Tinarelli1, Lorenzo Peretto1
1Department of Electrical, Electronic and Information Engineering, Guglielmo Marconi Alma Mater Studiorum, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, Italy.
Sensors (Basel, Switzerland)
|November 13, 2025
概括
引入新的电力质量指数 (PQ),以帮助研究人员和运营商识别不断发展的电力系统中的问题. 这些灵活的工具可以在各种频率和应用中提供高效的评估,以更好地监控网络.
科学领域:
- 电气工程 电气工程
- 电力系统分析 分析 分析
背景情况:
- 随着电子设备和可再生能源的整合,电力系统正在经历重大演变.
- 这种整合,在推动创新和减少对化石燃料的依赖的同时,导致电力质量 (PQ) 显著下降.
- 现有的文献广泛涵盖了不良PQ对电力资产的影响以及潜在的缓解策略.
研究的目的:
- 从现有指标中引入新的电力质量指数.
- 为研究人员和系统运营商提供简单,高效的工具,以识别监控网络中的PQ问题.
- 开发独立于获取条件的灵活指数,适用于广泛的频率和应用.
主要方法:
- 基于现有指标开发新的PQ指数.
- 使用合成和现实世界的信号数据验证这些指数.
- 对各种电压波形的索引应用的演示,包括测量活动的案例研究.
主要成果:
- 新获得的PQ指数在不同类型的信号上得到了有效性验证.
- 这些指数表明适用于广泛的频率范围 (50 Hz-150 kHz).
- 案例研究结果显示,在识别PQ问题方面表现有前途.
结论:
- 新的PQ指数为电力质量评估的现有指标提供了有价值的补充.
- 这些指数可以增强对电网PQ问题的理解和分类.
- 它们为改善电力系统质量监测和管理提供了坚实的基础.
更多相关视频
相关概念视频
Average Power
999
In practical electrical applications, the concept of time-varying instantaneous power is not frequently utilized. Instead, focus shifts to the more practical quantity known as average power. Average power is determined by integrating the instantaneous power over a specified time period and subsequently dividing it by that duration.
999
Power Factor Correction
473
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
473
Power Factor
675
The power factor is defined as the ratio of average (or active) power to apparent power, as illustrated by the relation
675
Energy and Power Signals
1.1K
In an electrical system with a resistor, voltage and current signals facilitate the measurement of power and energy across the resistor. For a continuous-time signal, the total energy over a time interval is defined as the integral of the square of the signal's magnitude over that interval. Mathematically, this is expressed as:
1.1K
Expected Frequencies in Goodness-of-Fit Tests
7.1K
A goodness-of-fit test is conducted to determine whether the observed frequency values are statistically similar to the frequencies expected for the dataset. Suppose the expected frequencies for a dataset are equal such as when predicting the frequency of any number appearing when casting a die. In that case, the expected frequency is the ratio of the total number of observations (n) to the number of categories (k).
7.1K
Frequency-Domain Interpretation of PD Control
339
Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
The proportional control gain, combined with the...
339