对印尼实施LUCF缓解与NDC目标的成本分析
Annuri Rossita1,2, Rizaldi Boer3,4
1Center for Climate Risk and Opportunity Management for Southeast Asia and Pacific (CCROM SEAP), IPB University, Bogor, 16143, Indonesia. annurirossita@gmail.com.
Carbon balance and management
|November 14, 2025
概括
印度尼西亚 印度尼西亚 印度尼西亚
科学领域:
- 环境经济学环境经济学
- 气候变化缓解减缓 气候变化缓解减缓
- 林业和土地使用政策
背景情况:
- 印尼通过联合国气候变化框架公约 (UNFCCC) 承诺减少排放.
- 土地利用变化和林业 (LUCF) 部门,特别是泥炭地,是实现印尼气候目标的关键.
- 以前对LUCF缓解的成本评估已经过时,并且经常排除间接和交易成本.
研究的目的:
- 评估印尼实施LUCF减缓战略的总成本.
- 在缓解成本评估中包括正式的交易成本.
- 为有效的气候变化减缓规划和私营部门参与提供信息.
主要方法:
- 使用了综合缓解评估过程 (COMAP) 模型.
- 在COMAP模型中,评估了减缓活动的碳和经济影响.
- 分析了森林保护和泥炭地管理的成本.
主要成果:
- 每公的LUCF缓解成本从10美元到3200美元不等.
- 实现印度尼西亚无条件的国家自主贡献 (NDC) 目标需要11.229亿美元 (投资) 和3.42亿美元 (生命周期成本).
- 预计私营部门将为53%的总成本提供资金.
结论:
- 私营部门的缓解活动由于大量的间接 (10-43%) 和交易成本 (4-19%) 而导致更高的生命周期成本.
- 需要政策工具来降低交易成本并鼓励私营部门参与.
- 多元化融资来源对于印尼履行气候承诺至关重要.
相关概念视频
Load-frequency control
583
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
583
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
268
Flood risk assessment involves careful planning and analysis to ensure the safety of communities near water retention structures. Capacity contours are a vital tool in this process, as they illustrate the potential spread of water at specific levels in a given area. In the context of building a bund across a small valley, these contours play a critical role in evaluating the safety of nearby residential areas.In this example, the bund is intended to store stormwater in the valley. The engineers...
268
Node Analysis for AC Circuits
606
Consider an angioplasty system featuring a catheter equipped with a turbine, a critical tool for removing plaque deposits from coronary arteries. This intricate medical device operates using a circuit model reminiscent of a dual-node RLC circuit powered by a current-controlled voltage source.
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
606
Power Factor Correction
458
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
458