在水溶液中测量乳酸盐,酸盐及其混合物的特拉赫兹光谱量化
Jiao Hu1,2,3, Mingkun Zhang1,2, Yuansen Guo1,2,3
1Center of Super-Resolution Optics and Chongqing Engineering Research Center of High-Resolution and Three-Dimensional Dynamic Imaging Technology, Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China.
Analytical chemistry
|November 17, 2025
概括
太赫兹 (THz) 谱学可以区分和量化溶液中的乳酸盐和酸盐混合物. 这种方法准确地确定水溶液和人工血液中的度,显示THz光谱学.
科学领域:
- 分析化学 分析化学
- 生物物理学的生物物理.
- 频谱学是一种光谱学.
背景情况:
- 在水溶液中定量有机混合物对于生物医学和化学分析至关重要.
- 太赫兹 (THz) 光谱为分析分子相互作用提供了一种非侵入性方法.
- 区分结构相似的有机分子,如乳酸盐和酸盐呈现分析挑战.
研究的目的:
- 调查THz光谱对于量化乳酸盐和酸盐混合物的有用性.
- 开发一种方法来同时确定水溶液中的乳酸盐和酸盐度.
- 评估THz光谱在生物流体矩阵中的适用性.
主要方法:
- 太赫兹 (THz) 光谱法用于分析乳酸盐 (Lac),酸盐 (Pyr) 和它们的混合物的溶液.
- 折射率 (n) 和灭绝系数 (k) 的测量与不同度相关.
- 用分子动力学模拟来理解光谱特征的起源.
主要成果:
- 乳酸盐和酸盐溶液表现出明显的THz光谱特征,尽管结构相似.
- 折射率 (n) 和灭绝系数 (k) 显示,随着度的增加,线性下降.
- 开发了一种方法来准确确定三元溶液和人工血液中的Lac和Pyr的总度和质量分数.
结论:
- 太赫兹 (THz) 谱学对于在水性混合物中的乳酸盐和酸盐的分化和定量是有效的.
- 开发的方法可以同时确定这些有机酸的度.
- 太赫兹光谱显示了在生物流体中分析有机混合物的巨大潜力.
相关概念视频
Measuring Reaction Rates
23.5K
Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical...
23.5K
Spectrophotometry: Introduction
8.4K
Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
8.4K
UV–Vis Spectroscopy: Beer–Lambert Law
7.6K
The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The modern...
7.6K
UV–Vis Spectrometers
4.0K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
4.0K
High-Performance Liquid Chromatography: Types of Detectors
2.3K
The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
2.3K
Conductometric Titrations: Strong Acid-Base and Weak Acid-Base Titrations
199
In acid-base titrations, conductance measurements are utilized to detect the endpoint. This method is grounded on the fact that electrical conductance relies on the number and mobility of ions. For instance, consider titrating strong acid HCl with a strong NaOH base. Initially, the HCl in the conductivity vessel conducts electricity due to the presence of hydrogen ions and chloride ions. As NaOH is gradually added from the burette, the fast-moving hydrogen ions are replaced by slower-moving...
199