[使用IFCC标准化毛细血管电泳法在CDT测量中的好处]
Jean-Pascal Siest1, Isabelle Bertin-Jung2, François Schellenberg3
1Biologie Prospective, Villers-lès-Nancy, France, Stabiligen, Villers-lès-Nancy, France.
Annales de biologie clinique
|November 20, 2025
概括
标准化碳水化合物缺乏转激素 (CDT) 血液测试可以改善酒精消费的监测. IFCC标准化程序显著减少了实验室结果的变化,提高了诊断可靠性.
科学领域:
- 临床化学 临床化学
- 生物标记分析 生物标记分析
- 实验室医学 实验室医学
背景情况:
- 碳水化合物缺乏转激素 (CDT) 是监测酒精消费的关键生物标志物.
- 在CDT测量方法中缺乏标准化导致参考值的显著变化.
- 标准化对于CDT测试的广泛采用和可靠性至关重要.
研究的目的:
- 将"经典"毛细管电泳 (CE) 方法的结果与IFCC标准化的CE程序进行比较.
- 评估标准化对实验室间变异性和与参考方法相关性的影响.
- 为了证明IFCC参考方法对CDT测定同质化的好处.
主要方法:
- 利用了2019-2024年的外部质量控制数据.
- 商业毛细管电泳方法的"经典"程序与其IFCC标准化程序的结果进行了比较.
- 评估了与并行高性能液体染色学 (HPLC) 参考方法的相关性.
主要成果:
- 通过标准化程序观察到实验室间结果分散率减少了40%.
- 证明了"标准"和IFCC程序之间的良好相关性.
- 显示了标准化程序与参考HPLC方法的调整.
结论:
- 国际碳水化合物委员会标准化程序显著使碳水化合物缺乏转激素 (CDT) 测定结果同质化.
- 标准化提高了实验室间CDT测量的可靠性和可比性.
- 建议采用IFCC标准,以改善酒精消费的查和监测.
相关概念视频
Capillary Electrophoresis: Applications
1.1K
Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
1.1K
Capillary Electrophoresis: Instrumentation
911
Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
911
Electrophoresis: Overview
3.5K
Electrophoresis is a powerful analytical separation technique that relies on the differential migration of charged species when subjected to an electric field. The core strength of electrophoresis lies in its ability to separate high-molecular-weight species in complex mixtures. It has found widespread use in biochemistry, molecular biology, and analytical chemistry, allowing the separation of compounds like amino acids, nucleotides, carbohydrates, and proteins with excellent resolution.
There...
There...
3.5K
Controlled-Current Coulometry: Coulometric Titration
488
Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
488
Controlled-Current Coulometry: Overview
626
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
626
Coulometry: Overview
2.2K
Coulometry is one of the rapid, most accurate, and precise analytical techniques that determine the quantity of an analyte by measuring the electrical charge needed for its complete electrolysis without using any analytical standards. The total charge passed during electrolysis correlates with the analyte amount by Faraday's laws of electrolysis. For accurate coulometric measurements, a charge equal to Faraday's constant multiplied by the number of electrons involved in the relevant...
2.2K