灾难性的更新:什么让中断器更具破坏性?
Wusheng Liang1, Christopher A Brown2, Abigail L Noyce3
1Department of Electrical and Computer Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213, USA.
The Journal of the Acoustical Society of America
|November 20, 2025
概括
突出的中断会扰乱听觉注意力和记忆回忆. 无法预测的声音和更长的目标序列加剧了这种中断效应,影响了焦点和工作记忆.
科学领域:
- 认知心理学 认知心理学
- 听觉神经科学 听觉神经科学
背景情况:
- 选择性注意力对于专注于听觉信息至关重要.
- 突出的中断可以损害回忆准确性,称为中断效应.
研究的目的:
- 调查影响中断效应大小的因素.
- 检查听觉注意力中的新奇性,工作记忆负载和中断器可预测性.
主要方法:
- 听众执行了一个听觉空间注意力任务,区分目标和分心流.
- 不能预测的听力中断在不同的时间点被引入.
- 在不同的条件下测量了目标音节的回忆精度.
主要成果:
- 断路器的新性没有影响中断效应.
- 增加工作内存负载 (目标序列长度) 放大了中断效应.
- 不能预测的中断器会比可预测的中断器造成更大的中断.
结论:
- 听觉中断显著影响了自上而下的注意力和工作记忆的维护.
- 干扰器的可预测性和工作记忆负载是注意力干扰的关键因素.
相关概念视频
Circuit Breaker and Fuse Selection
553
A circuit breaker is a device engineered to interrupt fault currents and sometimes reclose automatically. When a fault current is detected, the breaker separates the electrical contacts, which generates an arc. This arc is extinguished by methods such as elongation, cooling, or splitting, depending on the breaker's design. Breakers are categorized based on the voltage they operate at and the medium used for arc extinction, such as air, oil, SF6 gas, or vacuum.
In high-voltage systems,...
In high-voltage systems,...
553
Ecological Disturbance
20.6K
An ecological disturbance is a temporary disruption in the environment resulting from abiotic, biotic, or anthropogenic factors, causing a pronounced change in an ecosystem. The impact of an ecological disturbance, which can depend on its intensity, frequency, and spatial distribution, plays a significant role in shaping the species diversity within the ecosystem.
20.6K
Reclosers and Fuses
437
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
437
Sound Waves: Interference
4.5K
Sound waves can be modeled either as longitudinal waves, wherein the molecules of the medium oscillate around an equilibrium position, or as pressure waves. When two identical waves from the same source superimpose on each other, the combination of two crests or two troughs results in amplitude reinforcement known as constructive interference. If two identical waves, that are initially in phase, become out of phase because of different path lengths, the combination of crests with troughs...
4.5K
Series R—L Circuit Transients
361
In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
361
Line Protection with Impedance Relays
419
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
419