具有自动触发机制的规定的时间封闭控制,用于多无人机.
An Zhang1, Tianle Hou2, Wenhao Bi1
1School of Aeronautics, Northwestern Polytechnical University, Xi'an, 710072, Shaanxi, China; National Key Laboratory of Aircraft Configuration Design, Xi'an, 710072, Shaanxi, China.
ISA transactions
|November 20, 2025
概括
这项研究引入了一种新型的自动触发式制控制,用于多个无人机 (UAV) 在指定的时间内在领导者定义的边界内融合. 该方法显著减少了通信和控制器更新,提高了效率.
科学领域:
- 机器人技术 机器人技术 机器人技术
- 控制系统工程 控制系统工程
- 分布式系统 分布式系统
背景情况:
- 多个无人机 (UAV) 的合作控制提高了任务执行和操作安全.
- 现有的方法通常需要持续的通信和控制器更新,从而限制了效率.
- 在特定时间内实现封闭控制是一个重大挑战.
研究的目的:
- 为多个无人机开发一个规定的时间自动触发的封闭控制策略.
- 为了使追随者能够在任意指定的时间内汇聚在领导者定义的凸船体内.
- 为了减少通信和控制器更新频率,同时确保系统稳定性.
主要方法:
- 一个分布式的规定的时间观察员估计了领导状态和凸起的船体.
- 介绍了辅助状态来设计一个规定的时间封闭控制器.
- 开发了一个自动触发机制,以实现异步通信并降低更新速度.
主要成果:
- 拟议的方法保证在没有Zeno行为的情况下,在规定的时间内与凸船体的收.
- 在模拟中,通信频率减少了94.86%,控制器更新减少了92.65%.
- 硬件实验验证了控制算法的实际适用性.
结论:
- 开发的自动触发制控制有效地实现了多个无人机的规定的时间融合.
- 异步通信和降低更新频率提供了显著的实际优势.
- 该方法为合作无人机任务提供了强大而高效的解决方案.
相关概念视频
Time-Domain Interpretation of PD Control
355
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
355
Multi-input and Multi-variable systems
376
Cruise control systems in cars are designed as multi-input systems to maintain a driver's desired speed while compensating for external disturbances such as changes in terrain. The block diagram for a cruise control system typically includes two main inputs: the desired speed set by the driver and any external disturbances, such as the incline of the road. By adjusting the engine throttle, the system maintains the vehicle's speed as close to the desired value as possible.
In the absence of...
In the absence of...
376
PID Controller
631
Proportional-Integral-Derivative (PID) controllers are widely used in various control systems to enhance stability and performance. In a thermostat, it adjusts heating or cooling based on the temperature difference between the actual and desired levels. They are often used in automotive speed systems, effectively managing sudden speed changes while maintaining a constant speed under varying conditions. On the other hand, PI controllers, commonly employed in voltage regulation, enhance stability...
631
Phase-lead and Phase-lag Controllers
509
Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
509
Overcurrent Relays
471
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
471
Pilot and Numeric Relaying
464
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
464