基于事件触发机制的HVAC多代理系统共识节能算法的研究
Weilin Wu1,2, Shaoxiong Shi1,2, Meihuan Lin1,2
1Center for Applied Mathematics of Guangxi, College of Physics and Electronic Information, Guangxi Minzu University, Guangxi, China.
PloS one
|November 21, 2025
概括
本研究介绍了使用事件触发机制的HVAC系统的节能算法. 这种方法通过仅在必要时传输数据来减少网络负载,优化发电机调度.
科学领域:
- 控制工程 控制工程 控制工程
- 分布式系统 分布式系统
- 能源系统 能源系统
背景情况:
- 暖通空调系统需要高效的能源管理.
- 多代理系统为分布式控制提供了一个框架.
- 事件触发机制可以减少通信开销.
研究的目的:
- 为HVAC多代理系统设计一个节能算法.
- 使用事件触发机制降低网络传输压力.
- 为了实现分布式经济调度.
主要方法:
- 在HVAC多代理系统中使用事件触发机制.
- 在分布式经济调度中使用离散时间共识算法.
- 使用增量成本和效益作为一致性变量.
- 应用图形理论来建模通信拓.
- 使用共识算法分析系统稳定性和融合.
主要成果:
- 该算法成功实现了分布式经济调度.
- 信息传输是按需控制的,减少了网络压力.
- 模拟结果显示,增量成本趋于一个单一的价值.
- 触发时间是离散的,并且发生在不平等的周期中.
结论:
- 事件触发算法有效地减少了HVAC系统中的通信负载.
- 按需信息传输优化了能源调度.
- 该系统通过共识算法证明了稳定性和融合.
相关概念视频
Distributed Loads: Problem Solving
1.1K
Beams are structural elements commonly employed in engineering applications requiring different load-carrying capacities. The first step in analyzing a beam under a distributed load is to simplify the problem by dividing the load into smaller regions, which allows one to consider each region separately and calculate the magnitude of the equivalent resultant load acting on each portion of the beam. The magnitude of the equivalent resultant load for each region can be determined by calculating...
1.1K
Energy Conservation and Bernoulli's Equation
10.5K
Applying the conservation of energy principle or the work-energy theorem to an incompressible, inviscid fluid in laminar, steady, irrotational flow leads to Bernoulli's equation. It states that the sum of the fluid pressure, potential, and kinetic energy per unit volume is constant along a streamline.
All the terms in the equation have the dimension of energy per unit volume. The kinetic energy per unit volume is called the kinetic energy density, and the potential energy per unit volume is...
All the terms in the equation have the dimension of energy per unit volume. The kinetic energy per unit volume is called the kinetic energy density, and the potential energy per unit volume is...
10.5K
Conservation of Energy in Control Volume
1.1K
Consider a turbine operating under steady-flow conditions. The control volume is drawn around the turbine, with fluid entering at one point and exiting at another. The turbine extracts energy from the fluid, which performs mechanical work (shaft work).
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
1.1K
Conservation of Mechanical Energy
24.7K
The mechanical energy E of a system is the sum of its potential energy U and the kinetic energy K of the objects within it. What happens to this mechanical energy when only conservative forces cause energy transfers within the system—that is, when frictional and drag forces do not act on the objects in the system? Also assume that the system is isolated from its environment; in other words no external force from an object outside the system causes energy changes inside the system.
When a...
When a...
24.7K
Multi-input and Multi-variable systems
376
Cruise control systems in cars are designed as multi-input systems to maintain a driver's desired speed while compensating for external disturbances such as changes in terrain. The block diagram for a cruise control system typically includes two main inputs: the desired speed set by the driver and any external disturbances, such as the incline of the road. By adjusting the engine throttle, the system maintains the vehicle's speed as close to the desired value as possible.
In the absence of...
In the absence of...
376
Insulation Coordination
546
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
546