一种无交流电压传感器的预测电流控制方法,用于电网式逆变器,具有针对当前直流偏移电流的增强稳定性
Guolin Zhang1, Weidong Dong2, Lingfeng Meng3
1GD Power Development Co.,LTD, Beijing, 100101, China.
Scientific reports
|November 21, 2025
概括
本研究引入了一种新的方法,通过解决当前的直流偏移错误来改进网联逆变器控制. 增强的观察员和DC偏移补偿方法显著提高了稳定性和控制性能.
科学领域:
- 电气工程 电气工程
- 电力电子 电力电子 电力电子
- 控制系统 控制系统
背景情况:
- 电网式逆变器需要精确的电流控制,以实现高效的功率传输.
- 传统的无传感器预测电流控制方法易受当前直流偏移错误的影响,降低性能.
研究的目的:
- 开发一种无交流电压传感器的预测电流控制方法,对当前直流偏移错误有更强的稳定性.
- 为了提高在存在直流偏移时的网联逆变器的控制性能.
主要方法:
- 改进的电网电压观察器的设计,使用后退方法来减轻直流偏移的影响.
- 开发一种新的一次性直流偏移观察方法,用于准确估计和补偿.
- 将观察员集成到新的交流电压无传感器预测电流控制战略中.
主要成果:
- 改进的电网电压观察器有效消除了当前直流偏移的影响.
- 一次性DC偏移观察方法准确地估计和补偿DC偏移.
- 拟议的控制方法证明了对当前直流偏移的显著增强的稳定性.
结论:
- 这种新型的无传感器交流电压预测电流控制方法提供了对当前直流偏移的优越稳定性.
- 实验验证证了对网联逆变器提出的方法的有效性和可靠性.
更多相关视频
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
2.1K
10:16X-ray Beam Induced Current Measurements for Multi-Modal X-ray Microscopy of Solar Cells
Published on: August 20, 2019
14.4K
相关概念视频
Generator Voltage Control
605
Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand, use...
605
Fast Decoupled and DC Powerflow
715
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
715
Series R—L Circuit Transients
361
In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
361
Three-Phase Short Circuit—Unloaded Synchronous Machine
649
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
649
Controlled-Current Coulometry: Overview
626
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
626
Control of Power Flow
660
There are several methods to control power flow in power systems:
660