基于变压器-BiLSTM模型的空气质量指数的智能预测
Xinni Liu1,2, Kai Su3, Shubin Wang4
1School of Information, Xi'an University of Finance and Economics (XAUFE), No.360 Changning Street, Chang'an District, Xi'an, 710100, China. lxinni@xaufe.edu.cn.
Scientific reports
|November 25, 2025
概括
准确的空气质量预测对于公共卫生和环境管理至关重要. 结合变压器和BiLSTM网络的新混合深度学习模型显示,空气质量指数 (AQI) 的预测性能得到了改善.
科学领域:
- 环境科学 环境科学
- 计算机科学 计算机科学
- 数据科学数据科学数据科学
背景情况:
- 空气质量监测对于公共卫生,工业稳定和应对环境危害至关重要.
- 准确的空气质量指数 (AQI) 预测对于有效的环境管理和可持续发展至关重要.
研究的目的:
- 开发和评估混合深度学习模型,用于准确的AQI预测.
- 通过使用真实世界的空气质量数据,对比传统方法来评估模型的性能.
主要方法:
- 开发了一个混合深度学习模型,集成了一个变压器编码器和一个双向长短期存储器 (BiLSTM) 网络.
- 该模型在石家庄,北京和天津 (2013年11月至2025年2月) 的每日空气质量数据上进行了训练和验证.
主要成果:
- 变压器-BiLSTM模型展示了稳定可靠的AQI预测性能.
- 关键绩效指标包括RMSE为3.0012 ug/m3,MAE为1.7928 ug/m3,MAPE为3.3646%. 这两项指标均为3%.
- 与基线模型相比,混合模型表现出更高的准确性和概括性.
结论:
- 拟议的变压器-BiLSTM模型为AQI预测提供了一个可靠和可解释的工具.
- 这种方法为数据驱动的空气污染控制策略提供了定量支持.
相关概念视频
Transformers
1.7K
A device that transforms voltages from one value to another using induction is called a transformer. A transformer consists of two separate coils, or windings, wrapped around the same soft iron core. However, they are electrically insulated from each other.
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
1.7K
Energy Losses in Transformers
1.3K
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
1.3K
The Ideal Transformer
1.3K
In single-phase two-winding transformers, two windings are coiled around a magnetic core characterized by cross-sectional area A and magnetic permeability μ. A phasor current i1 enters the left winding while i2 exits the right winding, establishing the fundamental working of the transformer through electromagnetic principles.
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's tangential...
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's tangential...
1.3K
Transformers in Distribution System
486
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
486
Three-Winding Transformers
666
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
666
Transformers with Off-Nominal Turns Ratios
495
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
495