破碎的旋转杆故障检测用于反转器-引电机与负序列电流分析
Sarvarbek Ruzimov1, Jianzhong Zhang1, Xu Huang1
1School of Electrical Engineering, Southeast University, Nanjing 210096, China.
Sensors (Basel, Switzerland)
|November 27, 2025
概括
负序电流分析有效地检测了感应电机中断裂的转子杆. 先进的过技术在各种操作条件下提高了诊断可靠性.
科学领域:
- 电气工程 电气工程
- 机械工程 机械工程
- 状态监控 状态监控
背景情况:
- 感应电机在工业应用中至关重要.
- 断裂的转子杆是常见的发动机故障.
- 准确的故障检测对于运行可靠性至关重要.
研究的目的:
- 为了评估负序列电流分析对断裂的旋转杆检测.
- 通过先进的过来提高诊断可靠性.
- 在不同的负载和速度条件下评估故障检测.
主要方法:
- 使用负序列电流分析.
- 应用了一种频谱跟踪混合适应式扩展卡尔曼波器来进行波隔离.
- 对故障检测准确度和灵敏度进行了评估.
主要成果:
- 逆变器诱导的波被有效地分离,产生了更清晰的信号.
- 在健康和缺陷的运动信号之间观察到可比的异常模式.
- 该方法证明了高故障可见性和清晰度.
结论:
- 负序电流分析是一种可靠的技术,用于检测断裂的转子杆.
- 基于卡尔曼波器的扩展波隔离显著提高了诊断性能.
- 该技术在各种操作条件和早期故障阶段具有弹性和有效性.
更多相关视频
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
12.1K
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
6.1K
相关概念视频
Three-Phase Short Circuit—Unloaded Synchronous Machine
649
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
649
Power System Three-Phase Short Circuits
509
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
509
Series R—L Circuit Transients
361
In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
361
Bus Impedance Matrix
489
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
489
Fault Types
389
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
389
Sequence Networks of Rotating Machines
473
A Y-connected synchronous generator, grounded through a neutral impedance, is designed to produce balanced internal phase voltages with only positive-sequence components. The generator's sequence networks include a source voltage that is exclusively in the positive-sequence network. The sequence components of line-to-ground voltages at the generator terminals illustrate this configuration.
Zero-sequence current induces a voltage drop across the generator's neutral impedance and other...
Zero-sequence current induces a voltage drop across the generator's neutral impedance and other...
473