通过气相离子/离子交联质谱法对蛋白质电荷状态对应物的结构差异化
Woo-Young Kang1, Arup Mondal1, Alberto Perez1
1Department of Chemistry, University of Florida.
概括
气相交联质谱法 (XL-MS) 揭示了无处不在的.
科学领域:
- 蛋白质组学和质谱学
- 结构生物学 结构生物学
- 生物物理化学 生物物理化学
背景情况:
- 了解气相蛋白质结构对于将生物和质谱 (MS) 发现联系起来至关重要.
- 离子移动性质谱法 (IM-MS) 提供了对蛋白质构造的洞察,但拓细节有限.
- 气相交联质谱 (XL-MS) 是一种较新的技术,用于探测局部三级结构.
研究的目的:
- 为了在各种电荷状态 (6+到11+) 中区分酒精变质的乌比奎丁离子的构造.
- 应用气相XL-MS使用N-hydroxysulfosuccinimide (NHS) 化学与硫-EGS交叉连接器.
- 作为电荷状态的函数,研究气相蛋白中的局部三级结构变化.
主要方法:
- 电子喷雾电离 (ESI) 在不同的电荷状态下产生了无处不在的离子.
- 使用N-hydroxysulfosuccinimide (NHS) 和硫-EGS的化学物质进行气相交联.
- 通过质谱测量对改性的分析,以确定交叉链接位点并推断构造.
主要成果:
- 气相XL-MS成功分化了从6+到11+电荷状态的乌比奎丁离子的构造.
- 具有6+到8+电荷状态的乌比奎离子表现出折叠的形状.
- 具有9+至11+电荷状态的乌比奎离子显示出未折叠的结构,与ESI观测一致.
结论:
- 气相XL-MS提供基于电荷状态的蛋白质局部三级结构变化的敏感检测.
- 该方法补充了气相结构生物学现有的MS技术.
- 这项研究展示了一种新的方法来分析气相中的蛋白质结构动态.
相关概念视频
Chemical Ionization (CI) Mass Spectrometry
1.4K
The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
1.4K
Peptide Identification Using Tandem Mass Spectrometry
8.1K
Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
8.1K
Two-dimensional Gel Electrophoresis
7.2K
Two-dimensional gel electrophoresis is a high-resolution protein separation method first introduced by O' Farrell and Klose in 1975. This method involves protein separation by two dimensions, mass and charge, making it more accurate than one-dimensional gel electrophoresis.
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
7.2K
Mass Spectrometry: Overview
8.1K
Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electron ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave behind a...
8.1K
Mass Spectrum: Interpretation
2.6K
An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
2.6K
Mass Spectrometry: Complex Analysis
1.5K
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
1.5K


