应用hp版本的有限元方法来灭模拟在轴对称MRI磁铁中的模拟
M S Miah1, P D Ledger2, A J Gil3
1School of Computer Science & Mathematics, Keele University, Keele, ST5 5BG UK.
概括
这项研究引入了一个数值模型来预测磁共振成像 (MRI) 扫描仪中的磁灭. 该模型准确预测超导磁铁的行为,提高MRI的安全性和可靠性.
科学领域:
- 物理 物理学 物理
- 工程 工程师 工程师 工程师
- 医疗成像医学成像
背景情况:
- 磁共振成像 (MRI) 扫描仪使用超导磁铁来产生强大,均的磁场.
- 超导体需要冷冷却 (大约4.2K) 才能保持超导.
- 核磁共振超导磁体中的缺陷可能导致加热和磁灭,超导性的损失.
研究的目的:
- 开发一个准确的数值模型来预测轴对称MRI扫描仪中的磁灭.
- 模拟磁灭事件期间的热和电磁行为.
主要方法:
- 采用了高顺序/hp版本的有限元素方法.
- 合热,电磁和电路方程得到了解决.
- 边界层元素被用来解决高梯度区域.
主要成果:
- 数值模型准确地预测了磁灭现象.
- 对于MRI磁体火预测的有限元素方法的证明有效性.
- 提供了验证模型准确性的数值结果.
结论:
- 开发的数值模型对于预测MRI扫描仪中的磁灭是有效的.
- 这种方法增强了对超导磁铁行为的理解和管理.
- 有助于提高MRI系统的安全性和运行可靠性.
相关概念视频
Magnetostatic Boundary Conditions
1.6K
An electric field suffers a discontinuity at a surface charge. Similarly, a magnetic field is discontinuous at a surface current. The perpendicular component of a magnetic field is continuous across the interface of two magnetic mediums. In contrast, its parallel component, perpendicular to the current, is discontinuous by the amount equal to the product of the vacuum permeability and the surface current. Like the scalar potential in electrostatics, the vector potential is also continuous...
1.6K
Potential Due to a Magnetized Object
752
Magnetic dipoles in magnetic materials are aligned when placed under an external magnetic field. For paramagnets and ferromagnets, dipole alignment occurs in the direction of the magnetic field. However, the dipoles align opposite to the field in the case of diamagnets. This state of magnetic polarization due to the external field is called magnetization. Magnetization is defined as the dipole moment per unit volume. It plays a similar role to polarization in electrostatics.
The vector...
The vector...
752
Magnetic Resonance Imaging
8.9K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
8.9K
Ampere-Maxwell's Law: Problem-Solving
1.1K
A parallel-plate capacitor with capacitance C, whose plates have area A and separation distance d, is connected to a resistor R and a battery of voltage V. The current starts to flow at t = 0. What is the displacement current between the capacitor plates at time t? From the properties of the capacitor, what is the corresponding real current?
To solve the problem, we can use the equations from the analysis of an RC circuit and Maxwell's version of Ampère's law.
For the first part of the...
To solve the problem, we can use the equations from the analysis of an RC circuit and Maxwell's version of Ampère's law.
For the first part of the...
1.1K
Atomic Nuclei: Nuclear Relaxation Processes
1.2K
In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis, the precessing magnetic moments are randomly oriented around the z-axis.
1.2K
Magnetic Field Of A Current Loop
6.2K
Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
6.2K