基于干扰观察器的多环比例反系统用于三相交流直流转换器的输出电压调节
Hosik Lee1, Dongpin Kim2, Hyun Chang Park1
1Green Mobility Team, Tenergy, 13453, Seongnam, Korea.
Scientific reports
|November 28, 2025
概括
本研究引入了基于干扰观察器 (DOB) 的调节器,用于交流/直流电源转换器,改进了电压和电流跟踪. 新型控制器增强了性能恢复,并在不确定的条件下拒绝稳定状态错误.
科学领域:
- 电气工程 电气工程
- 控制系统 控制系统
- 电力电子 电力电子 电力电子
背景情况:
- 交流/直流电源转换器面临来自非线性,参数变化和负载不确定性的挑战.
- 现有的控制策略往往难以在动态条件下保持精确的输出电压和电流跟踪.
研究的目的:
- 为三相交流/直流电源转换器提出一种基于干扰观察器 (DOB) 的新型无偏移输出电压调节器.
- 解决和补偿系统非线性,参数不确定性和负载变化.
- 为了增强性能恢复和稳定状态错误拒绝功能.
主要方法:
- 设计了一个包含干扰观察器 (DOB) 的多环控制器.
- 控制器使用由DOBs驱动的比例错误反和前补偿.
- 整合了DOB来支持内部和外部环节控制器,以改善动态.
主要成果:
- 拟议的基于DOB的调节器有效地稳定了输出电压和电流跟踪错误.
- 在性能恢复和稳定状态错误拒绝方面显著改善.
- 在三相3kW交流/直流电源转换器上的实验验证证了该技术的有效性.
结论:
- 基于干扰观察器的无偏移输出电压调节器为三相交流/直流电源转换器提供了强大的解决方案.
- 控制器有效地处理不确定性,从而带来更高的性能和错误拒绝.
- 拟议的方法在功率转换器控制方面取得了重大进展.
更多相关视频
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
2.1K
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
12.1K
相关概念视频
Time-Domain Interpretation of PD Control
351
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
351
Feedback control systems
663
Feedback control systems are categorized in various ways based on their design, analysis, and signal types.
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
663
Second-order Op Amp Circuits
603
Implementing second-order low-pass filters in audio systems is crucial in refining audio signals by eliminating undesirable high-frequency noise. These filters typically involve second-order op-amp circuits configured as voltage followers, encompassing two nodes with distinct storage elements.
The analysis of such circuits follows a systematic approach, similar to the second-order RLC circuits. In practical scenarios, bulky inductors are rarely employed due to their size and weight. This means...
The analysis of such circuits follows a systematic approach, similar to the second-order RLC circuits. In practical scenarios, bulky inductors are rarely employed due to their size and weight. This means...
603
Generation of Three-Phase Voltage
731
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
731
Effects of feedback
958
Feedback in control systems plays a critical role in shaping various operational parameters, extending beyond simple error reduction to influence stability, bandwidth, gain, impedance, and sensitivity. Understanding these effects requires examining a basic feedback system characterized by defined input, output, error, and feedback signals.
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
958
Parallel RLC Circuits
1.6K
Street lamps equipped with RLC surge protectors are an excellent example of applying circuit analysis in practical scenarios. These surge protectors safeguard the lamp's components against sudden voltage spikes.
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
1.6K