一个针状的3-omega传感器用于软材料和生物组织的导热度测量
Spencer P Alliston1, Chris Dames2
1Department of Mechanical Engineering, University of California, Berkeley, CA, 94720, USA. spencer.alliston@berkeley.edu.
Scientific reports
|November 29, 2025
概括
研究人员开发了一种可重复使用的针传感器,用于精确测量软材料,液体和组织中的导热率. 这项创新简化了用于储能和冷保存应用的热特性.
科学领域:
- 材料科学 材料科学 材料科学
- 热力工程是热力工程中的一个.
- 生物物理学的生物物理.
背景情况:
- 软材料,液体和生物组织对于储能,电化学系统和冷保存至关重要.
- 这些材料的实验性热特性提出了重大挑战.
研究的目的:
- 适应3-omega方法用于各种软材料的直接导热度测量.
- 推出一种新的,可重复使用的微型制造的针状传感器,用于现场热分析.
主要方法:
- 开发一个微纤维制成的针状传感器,用于3-omega方法.
- 传感器直接插入各种样品,包括液体,软固体和相变材料.
- 使用3D数值模型进行准确的数据分析和导热率提取.
主要成果:
- 证明了传感器的可重复使用性和通过直接入的热接触的方便性.
- 成功描述了冰,水,糖醇,石英和肝的导热性.
- 实现了高精度,结果在已确定的文献热导率值的3%以内.
结论:
- 针状的3-omega传感器为软材料的热特征提供了一种多功能和准确的方法.
- 这种技术适用于各种材料,包括那些经历相变的材料.
- 开发的传感器简化了用于能源,生物学和材料科学应用的热性质评估.
相关概念视频
Temperature Measurement Sites
3.1K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
3.1K
Equipments Used to Measure Body Temperature
1.7K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.7K
Assessing Body Temperature - Tympanic membrane
1.1K
Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
1.1K
Assessing Body Temperature - Oral
1.4K
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
1.4K


