相关实验视频
Updated: Jul 24, 2026

08:21
Wideband Optical Detector of Ultrasound for Medical Imaging Applications
Published on: May 11, 2014
11.7K
全光散射里埃分析用于50 MHz的超快速用户定位,用于光束方向光学无线通信
Optics letters
|December 1, 2025
概括
我们开发了一种全光学方法,用于在光束方向光学无线通信 (OWC) 中实现超快速定位. 该技术使用波长映射进行实时,低成本的用户定位,无需高速数字处理.
科学领域:
- 光学无线通信的无线通信
- 在本地化技术技术.
- 信号处理 信号处理
背景情况:
- 束方向光学无线通信 (OWC) 需要精确的实时用户定位,用于高容量的室内链接.
- 现有的本地化方法可能涉及复杂的硬件或高处理需求.
研究的目的:
- 提出和演示一个全光学,超快速定位方法,用于波长控制的光束方向的OWC.
- 为了实现实时,节能,用户特定的本地化.
主要方法:
- 利用用户位置和反射信号的波长之间的映射.
- 使用全光学频率编码和分散里埃变换 (DFT) 进行即时波长识别.
- 从光脉冲之间的时间间隔推导用户位置,避免高速检测和数字处理.
主要成果:
- 在50MHz运行的超快速定位的实验演示.
- 验证一个理论模型,显示即时频率和脉冲间隔之间的线性关系.
- 简单,低成本,节能的本地化解决方案的确认.
结论:
- 拟议的全光学方法实现了光束引导OWC系统中的超快速和实时用户定位.
- 将里埃分析转移到光学领域简化了本地化过程.
- 这种方法为未来的OWC应用提供了实用和高效的解决方案.
相关概念视频
UV–Vis Spectrometers
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
Atomic Emission Spectroscopy: Overview
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Electronic Distance Measuring Instruments
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short distances...

