改进基于人工智能的狗心脏病诊断,使用专家共识的听觉标签
概括
减少狗心脏声AI模型中的标签噪声显著提高了准确性. 结合多个专家意见和利用个体心脏周期,提高了检测神经膜病的分类性能.
科学领域:
- 兽医医学 兽医医学 兽医医学
- 人工智能的人工智能
- 心脏病学 心脏病学
背景情况:
- 噪音标签在兽医诊断中对人工智能模型培训提出了重大挑战.
- 专家评估犬耳听数据的模糊性可能会对分类性能产生负面影响.
- 密克索马托斯中枢病 (MMVD) 是狗常见的心脏病,通常使用听力诊断来诊断.
研究的目的:
- 检查犬类心脏声音记录 (HSR) 中的专家评估含糊性.
- 评估标签噪声对MMVDAI分类性能的影响.
- 通过多个专家意见,引入和评估标签降噪方法.
主要方法:
- 专家对140个HSR的数据集进行了标注,以测量全盘心脏声强度.
- 用多个专家意见来选择70个高质量的HSR,创建一个降噪的数据集.
- 三种分类算法 (AdaBoost,XGBoost,Random Forest) 在原始和降噪数据集上进行训练和评估,并利用单个心脏周期来扩展数据.
主要成果:
- 标签噪声降低显著提高了所有测试算法的分类准确性,XGBoost显示了最显著的收益.
- 对于轻度心脏声,灵敏度从37.71%增加到90.98%,特异性从76.70%增加到93.69%.
- 在中度 (灵敏度30.23%至55.81%,特异性64.56%至97.19%) 和大声/激动人心的声 (灵敏度58.28%至95.09%,特异性84.84%至89.69%) 中也观察到改善.
结论:
- 尽量减少标签噪声对于提高兽医心脏病学AI分类算法的性能至关重要.
- 结合多个专家意见有效地减少了狗心脏声数据集中的标签噪声.
- 通过利用个人心脏周期以及降噪策略,提高了MMVD检测的分类稳定性.
更多相关视频
10:53Dissection Techniques and Histological Sampling of the Heart in Large Animal Models for Cardiovascular Diseases
Published on: June 16, 2022
9.4K
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
16.6K
相关概念视频
Assessment of the Cardiovascular System IV: Auscultation
1.7K
Cardiac auscultation is a clinical skill used to assess heart function and detect abnormalities. It involves listening to heart sounds at specific anatomical locations through a stethoscope.
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
1.7K
Heart Sounds
3.2K
Heart sounds are generated by the turbulence in blood flow due to the closing of heart valves. These sounds are best perceived slightly away from the valves, where the blood flow disseminates the sound.
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
3.2K
Cardiovascular System Abnormal Findings II: Auscultation
529
Auscultation, an essential part of a heart examination, is done using a stethoscope. It provides crucial information about heart function and possible heart problems. Due to heart problems, abnormal sounds can be heard during systole or diastole. These sounds include S3 and S4 gallops, opening snaps, systolic clicks, and murmurs.
Abnormal Heart Sounds
Gallops:
Abnormal Heart Sounds
Gallops:
529