电风暴的实用5级临床尺度:风暴分类.
Raphaël Martins1, Miloud Cherbi2, Karim Benali3
1Univ Rennes, CHU Rennes, CIC 1414, INSERM, LTSI - UMR 1099, F-35000 Rennes, France.
European heart journal. Acute cardiovascular care
|December 4, 2025
概括
一个新的风暴电风暴 (ES) 分类系统有效地分层了30天死亡风险. 这种工具有助于标准化管理,死亡率从第一阶段的5%增加到第五阶段的50%.
科学领域:
- 心脏病学 心脏病学
- 密集护理医学 密集护理医学
- 临床分类系统临床分类系统
背景情况:
- 电风暴 (ES) 呈现异质的临床场景.
- 缺乏标准化的分类阻碍了风险分层和ES患者的协调护理.
研究的目的:
- 根据临床特征开发一种新的电风暴 (ES) 分类系统.
- 在患有ES的患者中对30天死亡风险进行分层.
主要方法:
- 来自四个高等医疗中心的788名ES患者 (2010-2023) 的回顾性分析.
- 开发五阶段的STORM严重性反应分类,包括治疗强度和临床参数.
- 主要结局:所有原因的30天死亡率.
主要成果:
- 根据STORM分类,患者被分为五个阶段 (STORM-1到STORM-5).
- 在STORM阶段观察到30天死亡率的显著逐步增加 (5.0%至50.0%,p<0.01).
- 整体30天死亡率为14.8%.
结论:
- 风暴分类系统有效地对ES患者的30天死亡风险进行分层.
- 该系统可以支持标准化的多学科风暴电气管理策略.
- 建议进行进一步的前性研究以验证.
相关概念视频
Insulation Coordination
544
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
544
Secondary Distribution
532
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
532
Routh-Hurwitz Criterion I
510
Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
510
Electrocardiogram Fundamentals
1.4K
Introduction
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
1.4K
Electrocardiogram
5.3K
An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
5.3K
Primary Distribution
513
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
513