基于脉冲形成网络的kA级矩形脉冲发生器波形质量的研究
Yi Zhou1, Bo-Yi Liu1,2, Yan-Zhao Xie1
1State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, China.
The Review of scientific instruments
|December 8, 2025
概括
这项研究优化了脉冲形成网络 (PFN) 的高电流,长脉冲应用. 新的方法减少波形问题,为像激光驱动器这样的系统提供先进的脉冲生成.
科学领域:
- 电气工程 电气工程
- 脉冲动力系统 脉冲动力系统
背景情况:
- 脉冲形成网络 (PFNs) 对于产生高压,短时间脉冲至关重要.
- 现有的PFN研究仅限于高电流,长脉冲宽度应用,阻碍了像脉冲激光驱动器这样的系统.
研究的目的:
- 研究,优化和设计一个高电流,长脉冲宽度的PFN.
- 为特定的高功率应用解决PFN技术的局限性.
主要方法:
- 采用PFN感应参数的复杂优化来减少超越和波纹.
- 利用简化的工程方法,改变第一阶段的电感,同时保持其他恒定.
- 系统地分析了在高电流,长脉冲发电中导致平板垂落的因素.
主要成果:
- 实现了201.5V / 1007.5A的矩形脉冲输出,电流下降率为7.56%.
- 证明可调节的脉冲宽度范围从30到219.10微秒.
- 开发了一个基于PFN的发电机,其最大重复频率为110Hz.
结论:
- 内部电阻,特别是来自电线电感器的电阻,被确定为平板垂落的主要原因.
- 有针对性的设计改进成功地在苛刻的条件下保持了高波形质量.
- 在高电流,长脉冲应用中,PFN性能取得了显著的进步.
相关概念视频
Rectangular and Triangular Pulse Function
1.8K
The unit rectangular pulse function is mathematically represented by a rectangular function centered at the origin with a height of one unit. This function is defined by two parameters: T, which specifies the center location of the pulse along the time axis, and τ, which determines the pulse duration.
For example, consider a rectangular pulse with a 5V amplitude, a 3-second duration, and centered at t=2 seconds. This pulse can be expressed using the rectangular function, written as,
For example, consider a rectangular pulse with a 5V amplitude, a 3-second duration, and centered at t=2 seconds. This pulse can be expressed using the rectangular function, written as,
1.8K
Pulse amplitude and quality
2.9K
Pulse amplitude is a crucial indicator of cardiac health because it provides valuable insights into the strength of left ventricular contractions and the overall uniformity of blood circulation within the vasculature. The strength of the pulse is directly related to the force with which the heart contracts and the volume of blood being pumped.
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
2.9K
Voltammetric Techniques: Pulse Voltammetry
1.3K
Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
1.3K
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
1.7K
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
1.7K
Clipper Circuit
830
A clipper circuit is a fundamental wave-shaping device that harnesses the unique properties of diodes to alter and control waveform characteristics. This technology is widely used in electronic devices, especially in television and radar communication systems, where it enhances waveform modulation in both transmitters and receivers.
The operation of a clipper circuit can be exemplified by analyzing a dual-clipper configuration setup that integrates two ideal diodes, each paired with a biasing...
The operation of a clipper circuit can be exemplified by analyzing a dual-clipper configuration setup that integrates two ideal diodes, each paired with a biasing...
830
Pulse rhythm
1.3K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.3K