将海上风电场转化为协同聚合器,以加强可再生能源整合和电网灵活性 - - 东中国的一个例子
Da Xie1,2,3, Zhou Tian4, Chenghong Gu5
1Department of Electrical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China. xieda@sjtu.edu.cn.
Communications engineering
|December 8, 2025
概括
将海上风电场与储能和海洋牧场相结合,可以提高能源的吸收,并带来经济效益. 这种整体方法增强了中国东部的电网稳定性和粮食安全.
科学领域:
- 可再生能源系统可再生能源系统
- 整合海洋生态系统的整合
- 可持续发展 可持续发展 可持续发展
背景情况:
- 海上风能对全球能源转型至关重要.
- 目前的系统往往缺乏整合,限制了潜力.
- 整体系统提供更高的效率和价值.
研究的目的:
- 在中国东部开发和优化集成的海上风电集群.
- 评估这些集群的经济和环境效益.
- 为了证明能源和海洋资源之间的协同作用.
主要方法:
- 在中国东部的案例研究分析.
- 集成集群的优化 (风力发电场,发电厂,储存,海洋牧场).
- 对能量吸收,储存利用和频率调节的建模.
主要成果:
- 优化的集群显著提高了储能利用率和海上风力吸收率 (在20%的农场中高达95%).
- 与鱼作为灵活负载的集成提高了区域吸收率超过98%的速度.
- 实现了0.67 GWh的优化存储配置,每年经济效益为682亿元人民币和35千蛋白质.
结论:
- 综合性海上风电系统为能源和海洋资源管理提供了变革性的潜力.
- 这种模式增强了能源安全,经济效益和粮食安全.
- 该方法适用于其他具有适当政策和条件的地区.
相关概念视频
Generation of Three-Phase Voltage
731
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
731
Wind Turbine Machine Models
551
In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
551
Transformers in Distribution System
485
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
485
Generator Voltage Control
604
Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand, use...
604
Turbine-Governor Control
903
Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
903
Power Factor Correction
468
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
468