探索脉冲波速度作为血管血液动力学压力标记:不仅仅是动脉硬化?
Christopher Yuen1,2,3, Angela M Devlin4,3, Pascal Bernatchez1,2
1Department of Anesthesiology, Pharmacology and Therapeutics, Faculty of Medicine, The University of British Columbia (UBC), Vancouver, British Columbia, Canada.
American journal of physiology. Heart and circulatory physiology
|December 9, 2025
概括
动脉脉冲波速度 (PWV) 不仅仅衡量动脉硬度. 它反映了局部平衡的动态变化和动脉与整个身体之间的相互作用,提供了对血管健康的整体观点.
科学领域:
- 心血管生理学心血管生理学
- 生物医学工程 生物医学工程
- 血管生物学 血管生物学
背景情况:
- 动脉脉冲波速度 (PWV) 是评估动脉硬性的黄金标准.
- PWV可以预测心血管事件,如心肌梗塞,中风和心力衰竭.
- 新出现的数据表明,PWV也可能反映局部平衡和全身动脉相互作用.
研究的目的:
- 审查影响PWV的因素.
- 建议对这些因素进行一种新的分类,分为内在和外在.
- 将PWV重新定义为血管血动力学压力的整体衡量标准.
主要方法:
- 现有文献的叙述性审查.
- 分析内在因素 (动脉壁组成,平滑肌肉度,内皮功能).
- 对外部因素 (性别,血压,心率,代谢健康,年龄) 的分析.
主要成果:
- 内在因素包括弹性质,原,,平滑肌肉度和内皮功能.
- 外在因素包括性别,血压,心率,代谢健康和年龄.
- 如果只把PWV的增加看作是大动脉硬度,可能会过于简单化.
结论:
- 血管血动力压力 (PWV) 是对血管血动力压力的整体测量.
- PWV整合了机械,生化和结构/功能血管变化.
- PWV提供了比简单的动脉硬性评估更深入的见解.
相关概念视频
Pulse
1.9K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
1.9K
Assessing Blood pressure using a doppler ultrasound
2.3K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.3K
Cardiovascular System Abnormal Findings I: Inspection and Palpation
787
In a cardiovascular examination, inspection and palpation are crucial for identifying abnormalities.
Abnormal findings observed during an inspection
Abnormal findings observed during an inspection
787
Blood Pressure
9.3K
The movement of blood in a human body, commonly referred to as blood flow, is determined by the volume of blood that traverses a certain section of the bodily system per unit time. It is the rhythmic contraction of the heart's ventricles that primarily instigates this movement. As the ventricles contract, blood is forced into the prominent arteries, which then flow from areas of greater pressure to lower pressure areas. This movement continues into smaller arteries and arterioles and...
9.3K
Pulse amplitude and quality
2.9K
Pulse amplitude is a crucial indicator of cardiac health because it provides valuable insights into the strength of left ventricular contractions and the overall uniformity of blood circulation within the vasculature. The strength of the pulse is directly related to the force with which the heart contracts and the volume of blood being pumped.
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
2.9K
Assessment of the Cardiovascular System III: Palpation
969
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
969


