无线传感器网络的集中式双层集群方法,基于合级联模糊系统
Antonio Jesus Yuste-Delgado1, Alicia Triviño2, David Diaz-Jimenez3
1Department of Telecommunication Engineering, Universidad de Jaén, Linares, 23700, Spain.
Scientific reports
|December 10, 2025
概括
这项研究引入了使用级联模糊系统的双层集群方法,以提高无线传感器网络寿命. 该方法优化了集群头的选择,大大延长了网络寿命和能源效率.
科学领域:
- 计算机科学 计算机科学
- 电气工程 电气工程
- 网络工程 网络工程
背景情况:
- 物联网 (IoT) 应用经常使用无线传感器网络 (WSNs),需要高效的能源管理.
- 电池驱动的传感器节点需要策略来最大限度地提高网络寿命.
- 集群是WSN节能的一个关键技术,集群头的选择至关重要.
研究的目的:
- 为WSNs提出一种新的集中式,双层集群方法.
- 通过智能集群头和超级集群头选择来提高网络寿命和能源效率.
- 为了利用软计算,特别是模糊逻辑,提高WSN性能.
主要方法:
- 一个集中的,两层的集群架构,集群头 (CHs) 和超级集群头.
- 实施可持续性过器,以删除具有低残留能量的节点.
- 采用双级级联模糊系统,根据能量和其他变量选择CHs和超级CHs.
主要成果:
- 拟议的方法有效地规避了基站附近的快速能源耗尽.
- 在各种场景中,模拟显示了WSN寿命的大幅提高.
- 该方法显示了显著程度的适应性,以不同的基站位置.
结论:
- 级联模糊系统为WSN中的能源管理提供了强大的解决方案.
- 双层集群方法显著改善了网络的寿命和性能.
- 拟议的技术在各种WSN部署环境中具有适应性和有效性.
相关概念视频
Cascaded Op Amps
1.1K
Operational amplifiers (op-amps) are versatile electronic components that can be interconnected in a cascade - one after another in a linear sequence. This cascading is possible due to their infinite input resistance and zero output resistance, allowing them to maintain their input-output relationships even when connected in series.
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
1.1K
Signal and System
1.5K
A signal x(t) is a set of data or a time function representing a variable of interest. Signals typically convey information about a phenomenon, such as atmospheric temperature, humidity, human voice, television images, a dog's bark, or birdsongs. More generally, a signal can be a function of more than one independent variable. For instance, images depend on horizontal and vertical positions and can be regarded as two-dimensional signals. However, this text will focus on one-dimensional...
1.5K
Distributed Loads: Problem Solving
1.1K
Beams are structural elements commonly employed in engineering applications requiring different load-carrying capacities. The first step in analyzing a beam under a distributed load is to simplify the problem by dividing the load into smaller regions, which allows one to consider each region separately and calculate the magnitude of the equivalent resultant load acting on each portion of the beam. The magnitude of the equivalent resultant load for each region can be determined by calculating...
1.1K
Zones of Protection
737
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
737
SFG Algebra
296
In Signal Flow Graph (SFG) algebra, the value a node represents is determined by the sum of all signals entering that node. This summed value is then transmitted through every branch leaving the node, making the SFG a powerful tool for visualizing and analyzing control systems.
Each node in an SFG corresponds to a variable, and the interactions between nodes are represented by branches with associated gains. When multiple branches lead into a node, the value at that node is the sum of the...
Each node in an SFG corresponds to a variable, and the interactions between nodes are represented by branches with associated gains. When multiple branches lead into a node, the value at that node is the sum of the...
296
Reclosers and Fuses
431
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
431