使用内部压力测试对具有可控缺陷的聚乙烯管道使用寿命进行评估
Ioana-Daniela Manu1, Marius Gabriel Petrescu1, Cătălin Blag1
1Mechanical Engineering Department, Petroleum-Gas University of Ploiesti, 100680 Ploiesti, Romania.
Materials (Basel, Switzerland)
|December 11, 2025
概括
在HDPE管道中控制的缺陷显著降低了强度. 周边缺陷将使用寿命减少到83年,而纵向缺陷将其减少到69年,影响水基础设施的完整性.
科学领域:
- 材料科学 材料科学 材料科学
- 机械工程 机械工程
- 土木工程 土木工程是指土木工程.
背景情况:
- API 579-1/ASME FFS-1,第9部分指南定义了裂纹类缺陷.
- HDPE管道 (PE100,SDR 17) 对于水分系统至关重要.
- 了解缺陷的影响对于基础设施安全和寿命至关重要.
研究的目的:
- 为了评估受控,裂纹类型缺陷对HDPE水管强度的影响.
- 为了确定管道故障的临界压力,时间和缺陷深度.
- 为了估计不同缺陷方向的管道的剩余使用寿命.
主要方法:
- 具有诱导缺陷的HDPE管道的受控内部压力测试.
- 数字模拟用于分析压力和故障机制.
- 应用API 579-1/ASME FFS-1标准进行缺陷评估.
主要成果:
- 确定了临界压力 (Pcr),临界时间 (tcr) 和临界缺陷深度 (acr).
- 周围面向的缺陷导致剩余的使用寿命约为83年.
- 纵向的缺陷导致剩余的使用寿命约为69年.
结论:
- 控制的缺陷大大降低了HDPE水管的使用寿命.
- 缺陷方向在确定剩余的结构完整性方面发挥着至关重要的作用.
- 该研究为评估老化HDPE管道的安全性和维护提供了有价值的数据.
相关概念视频
Single Pipe Systems
412
In pipe flow analysis, problems are typically categorized into three types — Type I, Type II, and Type III — based on the known parameters and the desired outcome. Each type of problem addresses specific engineering requirements using fluid properties, pipe characteristics, and operational conditions.
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
412
Bending of Material: Problem Solving
473
In this lesson, determine the ratio of the maximum bending moments applied to two metal pipes, given that both pipes can withstand a maximum stress of 100 MPa. Both pipes have an outer radius of 1.8 cm. Pipe A has an inner radius of 1.5 cm, and Pipe B has an inner radius of 1 cm. The ratio of the maximum bending moment applied to two metallic pipes, each with a different inner and outer radius, is determined by considering their dimensions. The inner radius of the first pipe is 1.5 cm, and for...
473
Minor Losses in Pipes
1.8K
In pipe systems, minor losses refer to energy losses arising from components such as valves, bends, fittings, expansions, and other features that disrupt the steady flow of fluid. These disturbances cause energy dissipation through turbulence and resistance, which engineers quantify to manage system efficiency effectively.
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
1.8K
Multiple Pipe Systems
1.1K
Multipipe systems consist of complex configurations of interconnected pipes designed to transport fluids efficiently across intricate networks. They are essential in engineering applications requiring precise control over flow distribution, pressure, and head loss. They are categorized into series, parallel, loop, and network configurations, each distinguished by unique flow characteristics and applications.
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
1.1K
Testing Water Quality
330
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
330
Major Losses in Pipes
1.9K
When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
1.9K