使用诱导电荷检测来量化四极电动力学陷中的微滴的净电荷
Firoz Ahmed1, Michael I Jacobs1
1Department of Chemistry and Biochemistry, Texas State University, San Marcos, Texas 78666, USA.
The Review of scientific instruments
|December 11, 2025
概括
一种新的技术使用诱导电荷检测准确地测量微滴电荷. 这种方法实现了高精度,使得人们能够更深入地了解微滴化学和动态中的电荷效应.
科学领域:
- 分析化学 分析化学
- 物理化学 物理化学
- 电化学 电化学 电化学
背景情况:
- 精确的微滴电荷测量对于理解电荷在化学反应,离子分布和界面动态中的作用至关重要.
- 现有的非接触式电荷测量技术缺乏测量微米粒子电荷的灵敏度或能力,造成了重大研究缺口.
研究的目的:
- 介绍一种用于直接测量出于四极电动陷 (QET) 的微滴的净电荷的新技术.
- 为了能够精确地量化微滴的电荷,促进对电荷驱动的物理和化学过程的研究.
主要方法:
- 利用诱导电荷检测,其中微滴在圆柱状电极上诱导电荷 (Qinduced).
- 采用自制的电荷敏感预放大器 (CSP),具有长时间常数 (1.02 ± 0.01 s-1),用于准确检测缓慢移动的微滴.
- 通过将诱导电荷测量与法拉第杯 (QFaraday cup) 测量对约2900微滴进行比较,验证了该方法.
主要成果:
- 与法拉第杯测量相比,诱导电荷检测方法显示出高精度,绝对差异平均为<5 fC (精度为1%).
- Q诱导与Q法拉第杯密切相关,在一系列滴滴电荷,大小和速度上.
- 该技术在长时间 (高达100毫秒) 与检测电极相互作用的微滴上被证明是有效的.
结论:
- 开发的诱导电荷检测系统为测量微滴净电荷提供了灵敏而准确的方法.
- 这种技术解决了现有方法的局限性,可以适应各种基于滴滴的实验,包括滴滴列车研究.
- 该系统将推动研究电荷如何影响微滴的物理和化学处理,并可能揭示电荷加速化学机制.
相关概念视频
Mass Analyzers: Common Types
1.3K
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.3K
Electrospray Ionization (ESI) Mass Spectrometry
2.0K
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
2.0K
Coulometry: Overview
2.2K
Coulometry is one of the rapid, most accurate, and precise analytical techniques that determine the quantity of an analyte by measuring the electrical charge needed for its complete electrolysis without using any analytical standards. The total charge passed during electrolysis correlates with the analyte amount by Faraday's laws of electrolysis. For accurate coulometric measurements, a charge equal to Faraday's constant multiplied by the number of electrons involved in the relevant...
2.2K
Capillary Electrophoresis: Instrumentation
878
Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
878
Continuous Charge Distributions
7.9K
Imagine a bucket of water. It contains many molecules, of the order of 1026 molecules. Thus, although it contains discrete elements (molecules) at the microscopic level, macroscopically, it can be considered continuous. Small volume elements of water, infinitesimal compared to the bulk of the bucket's volume, still contain many molecules. Under this framework, quantized matter is approximated as continuous for practical purposes.
The electric charge can also be subjected to an analogical...
The electric charge can also be subjected to an analogical...
7.9K
Induced Electric Dipoles
4.7K
A permanent electric dipole orients itself along an external electric field. This rotation can be quantified by defining the potential energy because the external torque does work in rotating it. Then, the potential energy is minimum at the parallel configuration and maximum at the antiparallel configuration. While the former is a stable equilibrium, the latter is an unstable equilibrium.
Since the absolute value of potential energy holds no physical meaning, its zero value can be chosen as per...
Since the absolute value of potential energy holds no physical meaning, its zero value can be chosen as per...
4.7K