基于改进的风险评估方法的变压器维护策略,考虑到运营和维护成本
Hongbing Guo1, Yan Wang2, Hongbin Bo3
1Inner Mongolia Power (Group) Co., Ltd., Inner Mongolia Power Research Institute Branch, Hohhot, Inner Mongolia, China.
PloS one
|December 11, 2025
概括
本研究引入了改进的变压器维护风险分析方法,重点关注特定的故障模式,以优化资源配置和降低成本. 这提高了变压器的可靠性,降低了整体维护费用.
科学领域:
- 电气工程 电气工程
- 资产管理资产管理.
- 风险分析 风险分析
背景情况:
- 变压器对于工业电力供应至关重要,需要高可靠性.
- 目前的变压器维护策略缺乏针对特定故障模式的关注,导致资源分配效率低下.
- 传统的风险评估方法在考虑因素和权重分配方面存在局限性.
研究的目的:
- 为变压器制定一个以成本为导向的维护策略.
- 通过考虑特定的故障模式来解决当前维护策略的局限性.
- 改进对变压器故障的识别和预防.
主要方法:
- 开发了一种改进的风险分析方法.
- 该方法包含特定的变压器故障模式.
- 从改进的风险分析中得出一个以成本为导向的维护策略.
主要成果:
- 该研究确定了变压器的特定故障模式.
- 成功地应用了一种改进的风险分析方法.
- 获得了针对故障模式量身定制的以成本为导向的维护策略.
结论:
- 拟议的方法增强了变压器维护管理.
- 它可以更合理地分配维护资源.
- 该战略有效地降低了整体维护成本,提高了可靠性.
更多相关视频
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
2.1K
09:04A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
Published on: June 1, 2022
3.6K
相关概念视频
Energy Losses in Transformers
1.3K
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
1.3K
Reducing Line Loss
344
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
344
Transformers in Distribution System
475
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
475
Transformers with Off-Nominal Turns Ratios
491
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
491
Equivalent Circuits for Practical Transformers
1.3K
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
1.3K
Three-Winding Transformers
655
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
655