对于区域电网中低压的快速调节算法,在电网端具有高不确定性和高透率的风能和太阳能负载
Heran Kang1, Hongyang Liu1, Lijun Zhao1
1Economic and Technological Research Institute, State Grid East Inner Mongolia Electric Power Co., Ltd., Hohhot, China.
PloS one
|December 15, 2025
概括
这项研究介绍了一种快速的低压调节算法,以稳定具有高风能和太阳能集成的电网. 该算法准确预测功率波动,确保电网稳定性和可靠性.
科学领域:
- 电气工程 电气工程
- 可再生能源系统可再生能源系统
- 电力系统的稳定性 电力系统的稳定性
背景情况:
- 可再生能源 (风能和太阳能) 的高透率导致电网中的电压波动.
- 这些电源的固有不确定性和可变性挑战了电网稳定性.
研究的目的:
- 为具有显著风能和太阳能集成的电网开发快速低压调节算法.
- 为了提高电网的稳定性和可靠性,面对可再生能源的间歇性.
主要方法:
- 预测来自风力轮机,光伏和负载的输出功率波动.
- 构建一个具有安全性,效率和成本限制的多目标快速监管模型.
- 采用同时优化传输机制来快速调节电压.
主要成果:
- 该算法证明了对功率输出波动的高预测准确性.
- 实现了将电压快速恢复到正常水平.
- 电网稳定性保持在0.95以上的容忍水平.
结论:
- 拟议的算法有效地提高了电网稳定性和可靠性.
- 它为管理高可再生能源透率提供了一种实际的技术解决方案.
- 实现了对可变可再生能源的增强电网弹性.
相关概念视频
Load-frequency control
587
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
587
Generator Voltage Control
602
Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand, use...
602
The Power Flow Problem and Solution
781
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the power flow program computes...
781
Control of Power Flow
651
There are several methods to control power flow in power systems:
651
Fast Decoupled and DC Powerflow
708
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
708
Turbine-Governor Control
899
Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
899