概括
研究人员在对农产品的和多醇基物质 (PFAS) 分析中将复杂脂质确定为干扰物. 区分这些干扰物对于在复杂矩阵中准确检测PFAS至关重要.
科学领域:
- 环境化学环境化学
- 分析化学 分析化学
背景情况:
- 和多基基物质 (PFAS) 是广泛使用的具有环境持久性的化学物质.
- 由于潜在的干扰,在农产品等复杂矩阵中精确量化PFAS具有挑战性.
研究的目的:
- 为了识别在玉米,小提琴头和干草中对4:2甲基硫酸 (4:2 FTS) 的分析中观察到的干扰物.
- 开发方法来区分4:2 FTS与已识别的干扰物.
主要方法:
- 液体染色学-双重质谱学 (LC-MS/MS) 使用三重四极.
- 液体染色学 - 高分辨率质谱学 (LC-HRMS) 和MS/MS.
- 优化色谱条件和质谱过渡的优化.
主要成果:
- 科科脂肪酸F和其他复杂的脂质被确定为4:2 FTS的干扰物 (m/z 326.9743).
- 这些干扰物产生质量电荷比 (m/z) 为327.2177.
- 成功的分化策略包括HRMS,干扰物的有针对性监测和改变的染色分离.
结论:
- 复杂的脂质可以干扰农业样本中的 4:2 FTS分析.
- 实施先进的分析技术和方法调整可以减轻假阳性和PFAS的过度报告.
- 将已识别的干扰物添加到PFAS干扰清单 (PIL) 中,可以提高复杂样本矩阵的分析准确性.
更多相关视频
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
13.0K
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight MALDI-TOF Mass Spectrometry
Published on: June 10, 2018
26.1K
相关概念视频
Atomic Absorption Spectroscopy: Interference
2.0K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.0K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
1.2K
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.2K