在发电和网络稀缺条件下分配局部边际定价
Zejun Ruan1, Anthony Papavasiliou1, Mehdi Madani2
1Electrical and Computer Engineering, National Technical University of Athens, 9 Iroon Polytechniou St, Athens, 15772 Greece.
概括
将储备稀缺性定价整合到分布位置边际价格 (DLMP) 中可以改善投资信号. 准确的定价需要考虑网络拥堵和储备交付能力,以实现最佳的分布式能源系统.
科学领域:
- 电气工程 电气工程
- 能源系统 能源系统
- 市场设计市场设计
背景情况:
- 分布式能源 (DERs) 整合到电网中正在迅速推进.
- 现有的DER市场模式往往忽视了网络限制和储备短缺.
- 准确的定价机制对于高效的DER投资和电网运行至关重要.
研究的目的:
- 将储备稀缺性定价纳入分布位置边际价格 (DLMP).
- 分析网络拥堵和发电短缺对DLMP的影响.
- 评估市场设计,为分布式能源系统提供准确的投资信号.
主要方法:
- 为储备交付能力开发了一种计算可处理的配方.
- 使用注册盒配方,用于可扩展的应用到网格网络.
- 扩展了卡拉马尼斯模型,用于增强DER集成分析.
主要成果:
- 拟议的模型与辐射网络上的现有方法相当,并且可扩展到网格网络.
- 对储备交付能力的核算对DLMP和投资激励有重大影响.
- 分析揭示了在拥堵和各种流动场景下详细的DLMP定价模式.
结论:
- 储备稀缺性定价对于准确的DLMP和DER投资信号至关重要.
- 忽视网络约束和稀缺性定价导致扭曲的投资信号.
- 拟议的配方增强了对复杂的分销系统市场动态的理解.
相关概念视频
Maximum Power Flow and Line Loadability
574
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
574
Secondary Distribution
527
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
527
Uniform Distribution
5.9K
The uniform distribution is a continuous probability distribution of events with an equal probability of occurrence. This distribution is rectangular.
Two essential properties of this distribution are
Two essential properties of this distribution are
5.9K
Control of Power Flow
651
There are several methods to control power flow in power systems:
651
Primary Distribution
511
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
511
The Power Flow Problem and Solution
781
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the power flow program computes...
781