从燃烧子中产生的初级和二级有机气溶光吸收性质的进化解
Muhammad I Abdurrahman1, Chase K Glenn2, Robert Penland1
1School of Environmental, Civil, Agricultural, and Mechanical Engineering, University of Georgia, Athens, Georgia 30602, United States.
概括
生物质燃烧有机气溶 (POA和SOA) 在老化过程中发生光吸收变化. 二次有机气溶 (SOA) 形成和光漂白导致总体吸收减少,挑战了以前的估计方法.
科学领域:
- 大气化学 大气化学
- 气溶科学 气溶科学
- 摄影化学的使用.
背景情况:
- 生物质燃烧释放出初级有机气溶 (POA) 和二次有机气溶 (SOA).
- 这些气溶的吸光特性在大气老化过程中演变,影响气候.
- 了解这些光学变化对于气候建模至关重要.
研究的目的:
- 研究生物质燃烧POA和SOA在光化学老化过程中的光吸收性质的共同演变.
- 量化POA和SOA的折射率 (k) 的虚构部分的变化.
- 评估SOA光吸收估计间接方法的准确性.
主要方法:
- 的燃烧燃烧,以产生POA.
- 在氧化流反应堆 (OFR) 中的排放的光化学老化.
- 测量新鲜和老化的气溶的折射率 (k) 的虚构部分.
主要成果:
- 光化学老化导致POA略微增光,但形成吸收弱的SOA.
- SOA组件的光漂白速度很快,其低吸收率占主导地位,导致老化OA (AOA) 吸收率净下降.
- POA显示了最小的化学变化,而SOA经历了显著的转变.
结论:
- 二次有机气溶 (SOA) 的形成和光漂白会降低气溶的整体光吸收.
- 估计SOA吸收的间接方法可能会导致严重的高估.
- 必须考虑POA和SOA在老化过程中的明显光学演变.
相关概念视频
Atomic Emission Spectroscopy: Interference
576
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
576
Atomic Absorption Spectroscopy: Atomization Methods
1.4K
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
1.4K
UV–Vis Spectroscopy: Woodward–Fieser Rules
28.0K
UV–Visible absorption spectra of conjugated dienes arise from the lowest energy π → π* transitions. The light-absorbing part of the molecule is called the chromophore, and the substituents directly attached to the chromophore are called auxochromes. A strong correlation exists between the absorption maxima, λmax, and the structure of a conjugated π system. The Woodward–Fieser rules predict the value of λmax for a given structure by adding the...
28.0K
Flame Photometry: Lab
811
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
811
Atomic Emission Spectroscopy: Overview
3.4K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
3.4K
Atomic Absorption Spectroscopy: Radiation and Light Sources
1.1K
Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
1.1K