极端的板块边界局部化促进了日本沟的浅地震滑动
J D Kirkpatrick1, H M Savage2, C Regalla3
1Department of Geological Sciences and Engineering, University of Nevada, Reno, Reno, NV, USA.
概括
2011年东北地震显示,由于板块边界上的弱粘土层造成了巨大的浅滑. 这一发现表明其他具有相似地质的沉降区也可能经历大浅地震事件.
科学领域:
- 地质学
- 地震学
- 构造学
背景情况:
- 2011年东北9.1级地震在板块边界上呈现出前所未有的浅滑 (约50-70米).
- 了解控制浅滑的因素对于地震危险的评估至关重要.
研究的目的:
- 调查日本沟的物理特性和地质设置.
- 确定沉积层在控制大岩层的位置和滑动行为的作用.
主要方法:
- 来自国际海洋发现计划 (IODP) 405号探险队的钻井核心和地质日志的分析.
- 对进入太平洋板块的沉积层和物理性质的检查.
主要成果:
- 巨型岩层主要形成在沉积沉积物中的海底粘土层的顶部或底部.
- 这些粘土层在明显的机械接触时形成一个狭窄的,弱的断层区域.
- 这些接触物体的物理特性有着明显的对比性,使得它们可以在很浅的地方滑动.
结论:
- 浅板边界的薄弱海底粘土是导致诸如东北地震之类的大浅滑动事件的关键.
- 日本沟可能特别容易发生大浅滑裂,相比于缺少这种弱粘土层的边缘.
更多相关视频
07:39The Role of Fabric in Frictional Properties of Phyllosilicate-Rich Tectonic Faults
Published on: November 6, 2021
3.5K
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
27.5K
相关概念视频
Region of Convergence of Laplace Tarnsform
1.0K
The Region of Convergence (ROC) is a fundamental concept in signal processing and system analysis, particularly associated with the Laplace transform. The ROC represents an area in the complex plane where the Laplace transform of a given signal converges, determining the transform's applicability and utility.
Consider a decaying exponential signal that begins at a specific time. When deriving its Laplace transform, the time-domain variable is replaced with a complex variable. This...
Consider a decaying exponential signal that begins at a specific time. When deriving its Laplace transform, the time-domain variable is replaced with a complex variable. This...
1.0K
Elastic Strain Energy for Shearing Stresses
463
As discussed in previous lessons, strain energy in a material is the energy stored when it is elastically deformed, a concept crucial in materials science and mechanical engineering. This energy results from the internal work done against the cohesive forces within the material. When a material undergoes shearing stress and corresponding shearing strain, the strain energy density, which is the energy stored per unit volume, is calculated. Within the elastic limit, where the stress is...
463
Magnetostatic Boundary Conditions
1.6K
An electric field suffers a discontinuity at a surface charge. Similarly, a magnetic field is discontinuous at a surface current. The perpendicular component of a magnetic field is continuous across the interface of two magnetic mediums. In contrast, its parallel component, perpendicular to the current, is discontinuous by the amount equal to the product of the vacuum permeability and the surface current. Like the scalar potential in electrostatics, the vector potential is also continuous...
1.6K
Fluid Pressure over Flat Plate of Constant Width
2.4K
When a body is submerged in water, it experiences fluid pressure acting normal on its surface and distributed over its area. For better design structures, it is crucial to determine the magnitude and location of the resultant force acting on the surface. In the case of a rectangular plate of constant width submerged in water, the pressure increases with depth, resulting in a linearly varying trapezoidal pressure distribution from the upper to the lower edge of the plate.
The resultant force...
The resultant force...
2.4K
Equipotential Surfaces and Field Lines
4.8K
Electric potential can be pictorially represented as a three-dimensional surface. On such a surface, the electric potential is constant everywhere. The equipotential surface is always perpendicular to the electric field lines, and while it is three-dimensional, it can be treated as an equipotential line in a two-dimensional case. These equipotential lines are also always perpendicular to electric field lines. The term equipotential is often used as a noun, referring to an equipotential line or...
4.8K
Fault Types
388
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
388