是为了保护,还是为了恢复? 国防资源分配对网络稳固性的影响
Wei Chen1,2, Jingrui Wang2, Yongxiang Xia3
1Zhuoyue Honors College, Hangzhou Dianzi University, Hangzhou 310018, China.
Chaos (Woodbury, N.Y.)
|December 19, 2025
概括
捍卫者应该优先考虑保护而不是恢复,因为资源增长,然后回转. 为网络稳定性分配资源取决于防御成本和冗余性.
科学领域:
- 网络科学 网络科学
- 网络安全 网络安全
- 资源分配资源的分配.
背景情况:
- 网络稳定性对于系统弹性至关重要.
- 保护和恢复之间的平衡是防御者的关键.
- 了解最佳的资源配置是一个持续的挑战.
研究的目的:
- 调查保护和恢复之间的最佳资源配置.
- 在资源限制下最大限度地提高网络稳定性.
- 分析国防成本和网络冗余性的影响.
主要方法:
- 资源分配的数学建模.
- 对非线性资源分配动态的分析.
- 网络防御策略的模拟.
主要成果:
- 资源分配的非线性转移,从回收到保护,然后回到回收,随着资源的增加.
- 增加了用于恢复的拨款,并增加了关键节点的防御成本.
- 改进网络冗余性导致更多的资源分配用于恢复.
结论:
- 最佳的网络防御涉及到资源配置的动态转变.
- 防御成本和网络冗余性显著影响恢复资源分配.
- 节点优先级策略对于有效的资源管理至关重要.
相关概念视频
Distribution Reliability and Automation
474
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
474
Network Function of a Circuit
599
Frequency response analysis in electrical circuits provides vital insights into a circuit's behavior as the frequency of the input signal changes. The transfer function, a mathematical tool, is instrumental in understanding this behavior. It defines the relationship between phasor output and input and comes in four types: voltage gain, current gain, transfer impedance, and transfer admittance. The critical components of the transfer function are the poles and zeros.
599
Radial System Protection
409
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
409
Short-distance Transport of Resources
17.4K
Short-distance transport refers to transport that occurs over a distance of just 2-3 cells, crossing the plasma membrane in the process. Small uncharged molecules, such as oxygen, carbon dioxide, and water, can diffuse across the plasma membrane on their own. In contrast, ions and larger molecules require the assistance of transport proteins due to their charge or size. Transport across membranes also occurs within individual cells, playing a variety of essential roles for the plant as a whole.
17.4K
Zones of Protection
737
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
737
Relation Between the Distributed Load and Shear
1.1K
Understanding the relationship between the distributed load and shear force in structural analysis is crucial for analyzing beams subjected to various loading conditions. Consider the case of a beam experiencing a distributed load, two concentrated loads, and a couple moment.
1.1K

